During operation of the device, observe the rule that the maximum load does not exceed the values
specified in the table and the red symbol in the device chamber. The products should be arranged in such a
manner to allow free air circulation in the upright refrigerator or freezer.
The first filling of the refrigerated space should be done after cooling it earlier to the
operating temperature (the required time for the first cooling of the unloaded undercounter
refrigerator or freezer to the set-up temperature: ~ 2h). This rule should be observed also after
a longer break in operation.
It is not recommended to load the cabinet with non-refrigerated products (with a temperature
exceeding ambient temperature or containers with loose fluids as this could cause instant
icing of the system and increased consumption of electric energy and failure to reach the
lowest declared storage temperatures).
From time to time it is recommended to stop the operation of the device to clean its interior, defrost
naturally the evaporator unit, clean the condenser of the refrigeration unit and check the condition of the door
seal. A face heated by electric heater protects the seal against freezing in the freezing devices.
Any replacement of the seal consists in removing the old seal and pushing the new one in the groove of
the profile.
Before performing the afore-mentioned steps, it is necessary to switch off the device by means of a
main switch and remove the plug of connecting cable from the plug-in socket.
Condenser of refrigeration unit must be cleaned at least once every 4 weeks. To clean the condenser,
remove front shutter of the refrigeration unit chamber by removing (depending on model) two or four screws
by hand. For this use a soft brush or a vacuum cleaner.
It is not applicable to products connected to external refrigeration unit (no condensers are fitted).
Do not use a stream of water while cleaning the device. The producer does not assume
responsibility for the damages of the condensing unit arisen as a result of not maintaining the
condenser in a clean state!
The icing of the evaporator is removed automatically. The most frequent reason for the excessive icing
of the evaporator is the failure to observe the procedure of the pre-cooling of a product before placing it in
the freezing device.
All setups of the controller necessary for a normal function of the device are introduced by the producer
.
It is strictly forbidden to intervene in the system parameters of the controller because it may
cause very serious consequences, including damage of the goods and refrigerated
device. In case of the breakdown the goods stored in the device should be protected
against damage. Dora Metal does not assume responsibility for the goods damaged
as a result of the breakdown of the device.
The devices are provided with an automatic condensate evaporation system.
TRANSPORT
The producer delivers the device protected with cardboard angles and foil. During the transport the
device should be protected against moving.
The device should be transported in an operation position. Upon receipt of the device (before
unpacking) it is necessary to check if any damages did not arise during the transport. All noticed damages
should be immediately notified to the forwarder. In no case, a damaged device can be returned to its
producer, without notification, and without a written permit, received earlier from the producer.
The producer does not assume responsibility for the device that is damaged during the
transport.
DISPOSAL
Prior to the transport the device is protected by a packing which consists of the following recyclable
elements: wooden planks, cardboards, propylene fastening tapes, polyethylene foil.