Operation & Maintenance Manual
Measurement of Coolant Concentration
Special Tools
Figure
Product Number/Name
60.99901-0038 CC2602M (Fleet
guard number) Coolant test sheet
The coolant concentration can be measured as follows:
1. If the engine coolant temperature is within a range of 10 ~ 55°C, drain the coolant.
When taking out a sample of coolant from the supplementary tank, it is
diff cult to measure the precise concentration. Always take out sample
by opening the drain plug of coolant.
2. Soak the test sheet in the coolant and remove after 3 ~ 5 seconds. Shake the sheet
to remove the remaining coolant.
3. Wait for about 45 seconds until the test sheet changes its color.
Measurement time should not exceed 75 seconds. The color changes
as time passes.
4. Check the color on test sheet.
72
Summary of Contents for P185WDOU-T4F
Page 2: ......
Page 6: ...TABLE OF CONTENTS Operation Maintenance Manual TITLE PAGE...
Page 7: ...FOREWORD 9...
Page 10: ...12...
Page 11: ...SAFETY 13...
Page 19: ...SAFETY Operation Maintenance Manual Decals 21...
Page 20: ...Operation Maintenance Manual SAFETY 22...
Page 21: ...SAFETY Operation Maintenance Manual 23...
Page 22: ...24...
Page 23: ...NOISE EMISSION 25...
Page 30: ...32...
Page 31: ...GENERAL DATA 33...
Page 34: ...36...
Page 35: ...OPERATING INSTRUCTIONS 37...
Page 43: ...OPERATING INSTRUCTIONS Operation Maintenance Manual 45...
Page 51: ...ENGINE OPERATION 53...
Page 76: ...78...
Page 77: ...LUBRICATION 79...
Page 80: ...82...
Page 81: ...MAINTENANCE 83...
Page 90: ......
Page 91: ......
Page 92: ...94...
Page 93: ...TROUBLESHOOTING 95...
Page 102: ...104...