3-4 Operation
022-00029AE Operation and Maintenance Manual
6.
Rotate starter key to "START" position.
Starter motor should crank immediately,
and engine should start within a few
seconds.
7.
Release starter key when engine starts.
Key will return to "I" (ON) position.
8.
After engine starts, check all indicator lights and gauges to be certain that all engine systems (oil
pressure, oil temperature, coolant temperature, etc.) are in normal operating range. If any engine
system is not normal, turn starter key to "OFF" position.
NOTE:
Parking brake indicator light turns "ON" or "OFF" according to parking brake operation
despite engine starting.
9.
Perform “Hydraulic System Warm-up” on page 3-9.
10.
Check color of exhaust smoke
•
No color or light blue - Engine is running in good condition.
IMPORTANT
If engine does not start after
approximately 15 seconds of
cranking, release starter key. Wait 5
minutes for starter motor to cool
down. Repeat step 6.
Instrument Panel Light or Gauge
Indicator Reading
Fuel gauge
White Range
Engine coolant temperature gauge
Transmission oil temperature gauge
Engine oil pressure warning light
Off
Charging warning light
Brake oil pressure warning light
Parking brake light
On
HAOB350L
Figure 6
HAOB360L
Figure 7