G424F(FE) Service Manual
Chapter 6. LPG FUEL DELIVERY SYSTEM
179
DIAGRAM NOTES
Trim valves must be positioned
vertically with flow arrows in position
shown
Fuel outlet must be min 15
°
below horizontal position
Only one 90
°
fitting permissible on
vapor fuel line between mixer and
regulator (As shown the temp
sensor adaptor is considered the
one 90
°
fitting.)
Vapor fuel fittings (regulator and
mixer) must have minimum ID of
0.46” (11.68mm)
Vapor hose length to be as short as
possible and have no restrictions for
best regulator performance
N-2007 Regulator
Plastic WYE Fitting (black color)
for 7/32” (5.56mm) ID Tube
Hose
Valve (TEV Bosch Canister)
Plastic WYE Fitting (blue color)
for 7/32” (5.56mm) ID Tube
Hose
Adapter (temperature sensor)
Sensor (coolant, temperature)
Nipple (.625 hex 4mp, 2.5L
steel)
Solenoid (AFS Lock Off Valve)
Brass Tee Fitting. 1/4 Tube x 1/8
NPTF x 1/4 Tube
CA100 Mixer
1/4” (6.35mm) hose barb to 1/8”
(3.2mm) male pipe, 125HBL, .062
flow ID
1/4-28 UNF x 1/4” (6.35mm)
hose barb
1
2
2
6
7
8
3
4
8
4
5
9
11
3
10
12
1
Summary of Contents for G20P-5