Installation
1.
Install new O-ring on CMP sensor.
2.
Lubricate O-ring with clean engine oil.
3.
Install the CMP sensor into the CMP sensor
support plate.
Note:
Before installing retaining screw, verify the
CMP sensor is fully seated.
4.
Install retaining screw and lock washer. Tighten
retaining screw.
Tighten
• Bolts: 6 N
•
m(53lbf in).
5.
Connect the electrical connectors. Verify that the
connectors click/lock into place.
6.
Install harness clamp to CMP sensor support
plate.