OP000471
4-29
Inspection, Maintenance and Adjustment
500 HOUR / 3 MONTH SERVICE
Perform All Daily, 50 and 250 Hour
Service Checks
Replace Outer and Inner Air Cleaner
Elements
NOTE:
Replace outer element after cleaning 5 times or every
2,000 hours of service.
NOTE:
Replace inner element whenever a new outer
element is installed.
If there is clogged filter signal on the gauge panel, use the
following procedure.
1.
Open the access door at the hood.
2.
Remove the evacuator valve (1, Figure 42) and air
cleaner cover (2).
NOTE:
Inspect evacuator valve seal lips for wear or
damage. Replace valve if necessary. Install
evacuator valve with lips parallel to the cover.
3.
Remove outer filter (3, Figure 43) from the air cleaner
housing.
4.
Clean the air cleaner cover and the inside of the air
cleaner housing.
5.
Remove inner filter (4, Figure 43).
6.
Clean out inside of air cleaner housing. Do not use
compressed air to blow out housing.
7.
Install new inner filter. Do not clean and reuse inner
element.
8.
Install new outer filter.
9.
Install air cleaner cover and evacuator valve.
NOTE:
Make sure that all gaskets and cover are
properly installed and seated.
WARNING!
Never clean or attempt to remove the air cleaner
element if the engine is running.
Figure 42
2
1
FG007686
Figure 43
FG007687
4
3
Summary of Contents for DX35Z
Page 2: ......
Page 6: ...Table of Contents K1025196E IV Index 8 1 ...
Page 60: ...OP000468 Safety 1 54 ...
Page 90: ...OP000469 Operating Controls 2 30 ...
Page 132: ...OP000470 Operation 3 42 ...