 Loop  Info-Q-2-16

9

Continuous length of wire (NO Splices).

Cutaway of Underground Loops

1” Foam backer rod

spaced every 1 ft in saw cut

holds wires in place.

Sealant

1/2” to 3/4” Min.

Roadway

Sealant even with road surface.

Sealant even with road surface.

4 Turn Loop or Greater

3 Turn Loop or Less

1” depth

1 1/2” 
Typical

2”
Typical

3/16” to 1/4” Saw Cut

3/16” to 1/4” Saw Cut

Roadway

45° corner

saw cut.

45° corner

saw cut.

Straight

 

saw cut.

Drill approx. 1/2” hole in expansion joint (If existing)

to give loop 

wires 

room to move during roadway

exp

ansion and contraction

.

Straight

 

saw cut.

45° corner

saw cut.

Twist wire from this

point to loop detector

.

Exit Slot

NO Sharp

Angles

Wa

tertight J-Box

Sweep

Loop Lead-In Wire or Cable

to Operator in

PVC Conduit

Tape on end to hold

wires together

.

Straight

 

saw cut.

Straight

 

saw cut.

DO NOT allow the straight saw cuts to connect in 
the corners or the triangular roadway pieces that are 
created will eventually break free from the roadway.

Depth will vary
depending on the 
number of wire 
turns.

Backer Rod

Sealant

Note: Use only sweeps for 90° conduit bends. Do not 
use 90° elbows as this will make wire pulls very 
difficult and can cause damage to wire insulation.

NO 90° Elbows

Sweep

Drawings not to scale

Expansion   Joint (If existing)

1” foam backer rod

spaced ever

y 1 ft. in saw cut.

Summary of Contents for 9409 Dual Channel

Page 1: ...DoorKing Inc All rights reserved Underground Loops and Loop Detectors Underground Loops and Loop Detectors DoorKing Plug In Loop Detectors and Loop Accessories 9409 Dual Channel 9410 Single Channel 9...

Page 2: ......

Page 3: ...cellation Effect Field Enhancement Effect Loop Phasing Electrically Reverse the Phase of a Loop Loop Detection Field Interference and Loop Placement Saw Cut Loop Guidelines DoorKing Preformed Loop Gui...

Page 4: ...with a loop measuring 6 on the short leg Loops can be saw cut into concrete or asphalt They can be placed under brick pavers and asphalt or be imbedded in a poured concrete road surface Design Facts U...

Page 5: ...ne to its environment Stationary or static metal objects such as conduits pipes metal grates etc will not affect the loop field High voltage electrical power lines either underground or overhead can a...

Page 6: ...e height than a passenger car The height of detection above and below the loop is determined by the shortest leg of the loop The height of detection is equal to 1 2 to 2 3 the length of the SHORT LEG...

Page 7: ...ops in the opposite direction Clockwise or Counter Clockwise electrically creates the effect of the electrical current passing through the closest edges of the loops in the same direction Since the el...

Page 8: ...they must be the same size same number of turns and the same distance from the gate They must be connected in series and the direction in which each loop is wound is important for proper door or gate...

Page 9: ...ser to the gate than the short leg of the loop otherwise the movement of the gate will interfere with the loop s detection field and the loop detector will give a false call and reverse the gate s dir...

Page 10: ...od spaced approximately one 1 foot apart along the entire length of the saw cut and exit slot Make certain to press the backer rod tightly into the slot Use a wooden stick or other blunt instrument to...

Page 11: ...on Straight saw cut 45 corner saw cut Twist wire from this point to loop detector Exit Slot NO Sharp Angles Watertight J Box Sweep Loop Lead In Wire or Cable to Operator in PVC Conduit Tape on end to...

Page 12: ...and Gravel Base 1 Minimum Depth Hold Down Stakes Hold Down Stakes Styrofoam Blocks T connector accepts 1 2 PVC conduit Poured Concrete Asphalt 2 to 3 Depth Loop Lead In Wires T connector accepts 1 2 P...

Page 13: ...up to it Typically a loop lead in cable will need to be installed Pages 2 and 6 Loop should to be far enough away from the reverse loop to avoid any cross talk or on a different loop detector frequenc...

Page 14: ...detector frequency if detection fields overlap Page 7 Reverse Loop Optional Automatic Exit Loop Reverse Loop Shadow Loop Loop Lead In Wire Primary Operator Secondary Operator Loop Lead In Wires Loop L...

Page 15: ...er capable of testing up to 500 megohms 500 million ohms such as a DoorKing meter P N 9401 045 A typical ohms meter will not read units as small as micro henries Disconnect the loop wires from the loo...

Page 16: ...ate operators Manufactured by DoorKing Inc Megohm meter Checks integrity of ground loops Reads up to 500 megohms Asphalt sealant flat black 10 oz tube Concrete sealant gray 10 oz tube Two channel plug...

Page 17: ...Loop Detectors Underground Loops and Loop Detectors DoorKing Plug In Loop Detectors and Loop Accessories DoorKing Inc 120 S Glasgow Avenue Inglewood California 90301 U S A Phone 310 645 0023 Fax 310 6...

Reviews: