background image

1506-065-F-3-14  

Page 

5

 

Table of Contents 

 

IMPORTANT NOTICES............................................................................................................................................6 

 

SECTION 1 – INSTALLATION 

1.1 Mounting 

Dimensions ...............................................................................................................................7 

1.2 Wiring .......................................................................................................................................................9 

1.3 Wire 

Diagram............................................................................................................................................10 

1.4 Terminal 

Identification ..............................................................................................................................11 

1.5 

Aiphone Intercom Station Connections ....................................................................................................12 

1.6 

Secondary Keypad Wiring ........................................................................................................................13 

 

SECTION 2 – PROGRAMMING 

2.1 Master 

Code .............................................................................................................................................15 

2.2 

Relay Strike Time .....................................................................................................................................15 

2.3 X-Strikes 

Programming ............................................................................................................................15 

2.4 

Programming Four-digit Entry Codes .......................................................................................................16 

2.5 

Erasing Individual Four-digit Entry Codes ................................................................................................16 

2.6 

Erasing ALL Four-digit Entry Codes .........................................................................................................16 

2.7 

Four-digit entry Code Divide Number .......................................................................................................16 

2.8 

Programming Five-digit Entry Codes .......................................................................................................17 

2.9 

Erasing Individual Five-digit Entry Codes.................................................................................................17 

2.10 

Erasing ALL Five-digit Entry Codes .........................................................................................................17 

2.11 

Five-digit Entry Code Divide Number .......................................................................................................17 

2.12 

Hold Boundary Programming ...................................................................................................................18 

2.13 

Time Zone 1 Boundary Programming ......................................................................................................18 

2.14 

Time Zone 2 Boundary Programming ......................................................................................................18 

 

SECTION 3 – OPERATING INSTRUCTIONS 

3.1 Four-digit 

Entry 

Codes..............................................................................................................................19 

3.2 

Five-digit Entry Codes ..............................................................................................................................19 

3.3 

Request to Exit Input ................................................................................................................................19 

3.4 Door 

Open 

Input .......................................................................................................................................19 

3.5 

Hold Feature Operation ............................................................................................................................20 

3.6 Time 

Zone 

Operation ...............................................................................................................................21 

 

SECTION 4 – APPENDIX 

4.1 Troubleshooting........................................................................................................................................23 

4.2 Data 

Tables ..............................................................................................................................................24 

 

Log Sheet .................................................................................................................................................................25 

Summary of Contents for 1504-080

Page 1: ... Alone Digital Keypad Entry Devices Owner s Manual P N 1506 065 REV F 3 14 Copyright 2001 DoorKing Inc All rights reserved DoorKing Inc 120 Glasgow Avenue Inglewood California 90301 U S A Phone 310 645 0023 Fax 310 641 1586 www doorking com ...

Page 2: ...Page 2 1506 065 F 3 14 ...

Page 3: ... reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing Inc to notify any persons of any such revisions or changes Additionally DoorKing Inc makes no representations or warranties with respect to this manual This manual is copyrighted all rights reserved No portion of this manual may be copied reproduced translated or reduced t...

Page 4: ...Page 4 1506 065 F 3 14 ...

Page 5: ...ng ALL Four digit Entry Codes 16 2 7 Four digit entry Code Divide Number 16 2 8 Programming Five digit Entry Codes 17 2 9 Erasing Individual Five digit Entry Codes 17 2 10 Erasing ALL Five digit Entry Codes 17 2 11 Five digit Entry Code Divide Number 17 2 12 Hold Boundary Programming 18 2 13 Time Zone 1 Boundary Programming 18 2 14 Time Zone 2 Boundary Programming 18 SECTION 3 OPERATING INSTRUCTIO...

Page 6: ...nd gate operator or in such a way that a person cannot operate the entry system and touch the gate or gate operator at the same time Always disconnect power when performing service on the system If the unit is mounted outdoors be sure that the wiring to the unit is designed for direct under ground burial even if the wire is run inside a conduit Surge suppression is recommended on the low voltage i...

Page 7: ... pilaster or they can be mounted using a gooseneck mounting post p n 1200 045 or 1200 046 SECTION 1 INSTALLATION 1 0 7 8 9 6 5 4 3 2 10 0 5 25 2 875 6 125 3 0 5 0 2 5 2 5 875 1 25 1 31 875 Dia Model 1504 Surface Mount 6 375 4 375 2 5 2 5 25 875 5 25 1 2 3 6 5 4 9 8 7 0 Model 1506 Surface Mount ...

Page 8: ...ugh in box and wiring first and then install the keypad into the rough in box 1 2 3 6 5 4 9 8 7 0 7 125 8 375 6 625 4 0 2 56 75 875 4 25 4 375 875 5 375 7 0 2 25 2 25 1 25 2 0 4 0 5 625 4 375 4 25 1 25 875 2 125 75 1 875 2 875 3 875 875 25 25 25 10 24 STUD FLUSH MOUNT KEYPAD ROUGH IN BOX ROUGH IN BOX FLUSH KEYPAD ...

Page 9: ...a properly grounded metal conduit a cold water pipe or a grounding rod driven at least 10 feet into the soil A gooseneck post anchored or mounted on concrete does not make a good ground Avoid any splices in wiring If a splice is made it must be soldered and sealed in a watertight junction box Relay contacts are rated for 30 Volt 1 Amp A switch closure across terminals 1 and 12 will activate relay ...

Page 10: ...agram 6 2 3 4 5 12 11 1 10 9 8 7 14 13 GND Master Code ON OFF Electric Strike Magnetic Lock Power 16 VAC 20 VA Keypad Power Push to Exit Time Zone 2 Time Zone 1 Electric Strike Magnetic Lock Door Switch Gate Operator 1506 010 Circuit Board ...

Page 11: ...RMALLY CLOSED N C 7 RELAY 1 NORMALLY OPEN N O 8 RELAY 2 COMMON 9 RELAY 2 NORMALLY CLOSED N C 10 RELAY 2 NORMALLY OPEN N O 11 LOW VOLTAGE COMMON 12 LOW VOLTAGE COMMON 13 INPUT POWER 10 16 5 VAC or 12 24 VDC 14 INPUT POWER 10 16 5 VAC or 12 24 VDC NOTES A switch closure across terminals 1 and 12 will activate relay 1 for its programmed strike time Relay contacts are rated for 30 Volt 1 amp maximum p...

Page 12: ...e diagrams are provided for convenience only For detailed wiring information on Aiphone products visit their website at www aiphone com 1 E Aiphone LEF Master Station Red Red Blue Blue Push Button Speaker Red Red Blue Blue Push Button Speaker 47 uf 47 uf 1 E Aiphone LEM 1 Master Station ...

Page 13: ... 081 secondary keypad Pay careful attention to the terminal numbers as they can appear backwards numbered right to left when the faceplate is opened Use 22 AWG shielded cable maximum length 200 feet The secondary keypad has no relays Valid entry codes entered on the secondary keypad will activate the relays in the 1506 keypad 1599 010 Board 1506 081 Secondary Keypad To Main Terminals 13 and 14 To ...

Page 14: ...Page 14 1506 065 F 3 14 ...

Page 15: ...he amount of time that the relay s will be activated when a valid entry code is entered on the keypad The unit has two relays both of which can be programmed with individual strike times Setting the strike time to 00 will activate the relay for second The factory setting is 1 second 1 Press 03 and enter the four digit master code _ _ _ _ short beep 2 Enter the relay time in seconds _ _ 00 99 for r...

Page 16: ... have been erased 2 7 Four digit Entry Code Divide Number The four digit entry codes can be made to activate either relay 1 or relay 2 by programming a four digit divide number Four digit entry codes equal to or less than the divide number will activate relay 1 while four digit entry codes greater than the divide number will activate relay 2 If no divide number is programmed enter in step 2 then r...

Page 17: ...erased 2 11 Five digit Entry Code Divide Number The five digit entry codes can be made to activate either relay 1 or relay 2 by programming a five digit divide number Five digit entry codes equal to or less than the divide number will activate relay 1 while five digit entry codes greater than the divide number will activate relay 2 If no divide number is programmed enter in step 2 then relay 2 act...

Page 18: ...ime zone 1 establishes a set of four digit entry codes that will be denied access if the time zone 1 input terminal 3 is activated This time zone does not affect the five digit entry codes 1 Press 05 and enter the four digit master code _ _ _ _ short beep 2 Enter a four digit code for the lower boundary _ _ _ _ then press short beep 3 Enter a four digit code for the upper boundary _ _ _ _ then pre...

Page 19: ...rammed to operate either relay 1 or relay 2 When a five digit code is entered on the keypad the system checks its memory to see if the code is stored If the five digit entry code is not stored in the system memory the relay s will not activate If the five digit code is stored then the system will check the five digit divide number If the entered code is equal to or less than the divide number rela...

Page 20: ...d boundary will activate relay 2 indefinitely Five digit entry codes are not affected by hold boundaries To deactivate a relay that is latched simply re enter the number that was used to activate the relay See sample charts below Relay 1 Relay 2 Relay 1 momentarily activates with code 2000 or lower Divide Number 2000 Relay 2 momentarily activates with codes 2001 thru 2009 Lower Hold Boundary 2010 ...

Page 21: ...undaries may overlap each other Five digit entry codes are not time zone restricted Time Zone 1 Time Zone 2 Entry codes 1999 and lower are not time zone restricted Lower Boundary 2000 Entry codes 2000 thru 3000 are restricted by time zone 1 Upper Boundary 3000 Entry codes 3001 thru 3999 are not time zone restricted Lower Boundary 4000 Entry codes 4000 thru 5000 are restricted by time zone 2 Upper ...

Page 22: ...Page 22 1506 065 F 3 14 ...

Page 23: ...tricted Reprogram time zone or disable time zone input Be sure entry code is less than divide number or reprogram divide number Four digit entry codes will not activate relay 2 Be sure entry code is programmed into the keypad Press first then enter four digit number Code may be time zone restricted Reprogram time zone or disable time zone input Be sure entry code is greater than divide number or r...

Page 24: ...ables below to record data entered into the keypad system MASTER CODE 4 DIGIT HOLD BOUNDARIES LOWER UPPER 4 DIGIT DIVIDE NUMBER 5 DIGIT DIVIDE NUMBER TIME ZONE 1 BOUNDARIES LOWER UPPER TIME ZONE 2 BOUNDARIES LOWER UPPER 5 DIGIT ENTRY CODES 1 2 3 4 5 6 ...

Page 25: ...1506 065 F 3 14 Page 25 NAME 4 DIGIT CODE NAME 4 DIGIT CODE ...