background image

Pedestrian  ga

te

Do

or leaf

M

agnet

Twist

ed c

able

O

pen ga

te tr

ansmitt

er

Bott

om r

ubb

er seal

Terminal b

ox

W

all

Terminal b

ox

O

per

at

or 

connec

tion 

cable

Aper

ture heigh

t

1 DEscrIPTIOn

There  should  be  required  for  the  pedestrian  gates  forming  part  of  the 

sectional  door  leafs  to  install  a  device  which  would  prevent  the  electric 

operator from being started, when the pedestrian gate is in its open position. 

The WDKIT open gate transmitter kit is a magnet based contact-free sensor 

which  has  been  designed  to  be  inserted  into  the  pedestrian  gate  profile 

resulting part of a sectional door leaf. The required safety is then ensured by 

using a magnet and a reader to be connected to the external control panel. 

The  magnet  (to  the  left)  is  installed  on  the  pedestrian  gate  leaf,  while  the 

reader (to the right) is inserted into the door profile. When the pedestrian 

gate is in its closed position, the magnet and the reader are aligned between 

them and the contact in the control board is closed, while the door can be 

opened using the operator. When the pedestrian gate is opened the magnet 

and the reader are get shifted in relation to each other and the contact gets 

open, while the control board do not allow the operator to start.

2. TEcHnIcAL sPEcIFIcATIOn 

3. InsTALLATIOn

1.  Install  the  transmitter  kit  inside  the  door  leaf,  at  the  pedestrian  gate 

bottom (see the pedestrian gate transmitter kit installation diagram)

2.  Facing  the  transmitter,  the  magnet  is  then  to  be  installed  on  the 

pedestrian gate.

3. Install one terminal box on the door leaf and the other one on the wall, 

as shown in the diagram below.

4.  Install  the  required  cabling  from  the  transmitter  to  the  terminal  box 

installed on the door leaf.

5. Connect the two terminal boxes with the twisted cable provided with 

the kit.

6.  Connect  the  electric  operator  control  outlets    to  the  wall-installed 

terminal box outlets.

4. cOnnEcTIOns

OPEn PEDEsTrIAn gATE KIT InsTALLATIOn DIAgrAM

Power supply 

24V DC/AC

Operating temperature

-40° to +75°C 

Type of outlets

NC

Protection class

IP 68

OPEn PEDEsTrIAn gATE KIT 

(WIcKEDDOOr)

Open pedestrian gate 

transmitter kit with 

cable (3 m)

stop (nc)

Two on-door terminal 

boxes

Twisted cable for operator 

connection

Reviews: