DoorHan SLIDING-1300 Installation And Operation Manual Download Page 8

синий

красный

4.6. Placement of limit switches plates

Sliding-1300/2100  drive  is  equipped  with  ferreed 
contacts (magnetic reed switches) that are responsive 
to  the  movement  of  magnet  attached  to  the  rack  and 
generate a command to stop the door.
Install the limit magnets as follows.

1.    Release  the  drive  (see  sec.  “Release  mechanism 

operation”).

2.  Move the door manually to the opened position with 

2-5 cm to the mechanical stop

3.  Move the magnet of limit switch to open (triangular blue sticker) along the rack in the direction of door opening until magnetic 

reed switch is OFF. This can be seen by looking at the corresponding LED on the control board (see sec. “Control unit LEDs”). 
Slide the magnet in the same direction for approximately 2-3 cm and secure it to the rack.

4.  Move the door to the closed position with 2-5 cm to the mechanical stop.
5.  Move the magnet of limit switch to close (round red sticker) along the rack in the direction of door closing until magnetic reed 

switch is OFF. This can be seen at the appropriate LED on the control board (see sec. “Control unit LEDs”). Slide the magnet 
in the same direction for approximately 2-3 cm and secure it to the rack.

6.  Move the door to the middle position and lock the drive (see sec. “Release mechanism operation”).
7.  Provide at least 2 cm gap from the door to the mechanical stop in the extreme opened and closed positions to ensure quality 

operation of the system.

8.  Run several complete cycles of operation and verify the installation of limit switches. The drive shall stop upon reaching the 

limit switch with the corresponding LED goes out. SW1— LED for switch to close. SE2 — LED for switch to open.

9.  Distance from the limit switch to limit switch magnet shall be not more than 5 mm.

WARNING! 

Upon adjustment of limit positions, make sure of normal operation of limit switches: the corresponding LED 

on the control unit shall go out upon response. If the light does not go out, repeat the adjustment.

8

Installation notes for the rack

1. Never weld the racks to the collars or to each other.
2. Check that the door can reach mechanical stops, and there is no friction while moving the door.
3. Do not lubricate any rack or gear.

4.5. Installation of gear rack on third-party door

1. Move the leaf manually in one of its extreme positions.
2. Put the first part of the rack on the gear and install the collar between the rack and the door so that they coincide with the 

upper part of the slot.

3. Mark the drilling point on the door. Drill a hole of 6.5 mm and cut the thread using a tap M8. Tighten the bolt.
4. Move the leaf manually so that the rack remains on the gear and repeat step 3.
5. Attach another rack element against the previous one. Align the teeth of these two elements using free rack. Move the door 

manually and perform all operations in the same way as for the first element. Repeated as long as the door is not completely 
overlapped by racks.

90

23

Полотно ворот

Зубчатая рейка
Монтажное основание

Limit switch to close

Limit switch to open

Door leaf

Gear rack
Installation base

blue

red

DRIVE ASSEMBLY

Summary of Contents for SLIDING-1300

Page 1: ...DRIVE SLIDING 1300 2100 Installation and Operation Manual 3 4 5 5 9 9 9 OVERVIEW SAFETY PRECAUTIONS DRIVE ASSEMBLY INSTALLATION RELEASE MECHANISM OPERATION MAINTENANCE TROUBLESHOOTING DoorHan 2014...

Page 2: ...S 4 3 DRIVE ASSEMBLY 5 4 INSTALLATION 5 4 1 TOOLS 5 4 2 Drive installation and cabling diagram 5 4 3 Drive installation 6 4 4 Installation of gear rack on DoorHan door 7 4 5 Installation of gear rack...

Page 3: ...it is set inside the drive housing with a gear motor The drive has a low noise level and overheating protection Sliding 1300 2100 automatic drive serves to operate sliding door Do not use it for other...

Page 4: ...out prior approval of DoorHan y y Do not leave the motors in released position It can result in out of control door leaf movement and as a consequence to is damage y y Do not drive if the device requi...

Page 5: ...ox housing 2 Housing cover 3 Control unit 4 Stator 5 Capacitor 6 Terminal block 7 Gear 8 Drive mounting 9 Mounting cover 10 Release mechanism 11 Limit switches 3 DRIVE ASSEMBLY 4 INSTALLATION 8 1 5 7...

Page 6: ...be free from pipes or electrical cables y y If the motor is not protected from passing transport install the appropriate protection means to prevent from accidental impact y y Make sure of effective...

Page 7: ...ew the collar 6 on the bolt but do not tighten it Collar 6 shall press the clamp 5 to C profile 1 see figure 4 5 Repeat steps 2 4 for other mounting assemblies Their total number shall match the one o...

Page 8: ...8 Run several complete cycles of operation and verify the installation of limit switches The drive shall stop upon reaching the limit switch with the corresponding LED goes out SW1 LED for switch to...

Page 9: ...to release the drive When re leased the door may be opened and closed manually If it s necessary to open the door manually when power is off or drive fails use the release mechanism 1 Insert the key...

Page 10: ...NOTES...

Page 11: ...NOTES...

Page 12: ...our company and believe that you will be satisfied with its quality For information on purchasing distribution and servicing contact DoorHan central office at Kralovsky VRCH 2018 Kadan 43201 Czech Rep...