MENAPRO20032009
APRO 20
ENGLISH
SETTING FOR OPERATION
The
APRO 20
movement detector can be configured in mono direction mode (one
direction only) or in bi directional mode (in both directions).
Remove the rubber plug from the lower section of the detector (Fig. 1-A) and set the
required function through the dip-switch (Fig. 1-B), choosing from the possibilities
indicated in the table:
DSW1 DSW2 DSW4
SENSITIVITY
CONDITION
OFF
-
ON
Low
Movement is detected in both directions
OFF
-
OFF
High
Movement is detected in both directions
ON
OFF
ON
Low
Approach to the sensor is detected
ON
OFF
OFF
High
Approach to the sensor is detected
ON
ON
ON
Low
Movement away from the sensor is detected
ON
ON
OFF
High
Movement away from the sensor is detected
ASSEMBLY AND ORIENTATION
APRO 20
can be installed at the centre of the door to be controlled or on the side, on
non-vibrating structures (walls or ceiling) and at a maximum height of 6 m. Use the
template supplied to prepare the holes.
Fasten the device using the prepared holes, remove the lower cover (Fig. 2-A) and
loosen the screw that blocks the detector orientation. Direct the detector toward the area
to be controlled and lock in that position.
For correct operation, do not install
APRO 20
:
- facing the moving parts of the door
- facing fluorescent lights (minimum distance 2m)
- facing areas where rain could provoke water fluxes
These conditions could activate the device and cause the unwanted opening of the door.
ELECTRICAL CONNECTIONS
Connect the pre-wired cable as indicated in table 1 then power the detector.
Via Cagliari, 19 - Tel. +390112482361
10153 Torino - ITALIA