background image

               MENAPRO20032009

APRO 20

ENGLISH

SETTING FOR OPERATION

The

APRO 20

 movement detector can be configured in mono direction mode (one 

direction only) or in bi directional mode (in both directions). 
Remove the rubber plug from the lower section of the detector (Fig. 1-A) and set the 
required function through the dip-switch (Fig. 1-B), choosing from the possibilities 
indicated in the table: 

DSW1 DSW2 DSW4

SENSITIVITY

CONDITION

OFF

-

ON

Low

Movement is detected in both directions 

OFF

-

OFF

High

Movement is detected in both directions 

ON

OFF

ON

Low

Approach to the sensor is detected 

ON

OFF

OFF

High

Approach to the sensor is detected 

ON

ON

ON

Low

Movement away from the sensor is detected

ON

ON

OFF

High

Movement away from the sensor is detected

ASSEMBLY AND ORIENTATION

APRO 20

 can be installed at the centre of the door to be controlled or on the side, on

non-vibrating structures (walls or ceiling) and at a maximum height of 6 m. Use the 
template supplied to prepare the holes. 
Fasten the device using the prepared holes, remove the lower cover (Fig. 2-A) and 
loosen the screw that blocks the detector orientation. Direct the detector toward the area 
to be controlled and lock in that position.

For correct operation, do not install 

APRO 20

 : 

- facing the moving parts of the door 
- facing fluorescent lights (minimum distance 2m) 
- facing areas where rain could provoke water fluxes 

These conditions could activate the device and cause the unwanted opening of the door. 

ELECTRICAL CONNECTIONS 

Connect the pre-wired cable as indicated in table 1 then power the detector. 

                                                                                                      Via Cagliari, 19 - Tel. +390112482361

 10153 Torino - ITALIA