JZ1 SERIES PUMP
6.3 Reduce noise and vibration
6.3.1 Main measures
• Operate in optimum working conditions to avoid cavitation.
• Avoid resonance of inlet and outlet pipeline.
• Fix inlet and outlet pipelines.
6.3.2 Auxiliary measures
• Isolation measures can be used to isolate noise, such as sound insulation coverage, space isolation, etc.
6.4 Installation method
• Use base mounting to install the pump ,and the pump is mounted on a fixed mounting platform.
• Use base mounting to install (with adjustable support foot), the height of the support foot can be adjusted
freely to ensure the stable installation of the pump.
6.5 Pipeline installation
• Reduce pipe resistance as much as possible and
avoid to use unnecessary elbows and valves.
• When designing piping connection, try to avoid
causing pressure loss and avoid cavitation caused by
inhalation end
• The inlet and outlet control valves should be as close
as possible to the inlet and outlet end.
• Inhalation end pipeline should be as short as
possible
• The inlet end pipeline should be installed horizontally
to reduce the possibility of residual air in the pipeline.
• Design pipeline reasonably according to pressure,
temperature and medium characteristics.
• Avoid stress from pipes to pumps (pipes must be
supported independently)
Wrong pipe type
Right pipe type
8