background image

20 

DONG IL TECHNOLOGY LTD 

3.3 Cleaning of fan 

How to clean Fan 

① Be sure to disconnect power. 
② Loosen 4 screws and separate a filter cover/case. (Figure 1) 
③ Separate a fan softly to the back side of a product. 
④ Remove a foreign substance with a compressed air or soft cleaning 
equipment. (Figure 2) 
⑤ Assemble it in reverse order.

 

         A wire can be damaged with excessive assembly and disassembly, 

Figure 1 

Figure 2 

Warning 

Summary of Contents for ASF-AD Series

Page 1: ...tion manual before using the product in order to achieve maximum performance Keep this instruction manual within your reach after reading so that it can be used at any time 28 Namyang ro 930beon gil Hwaseong si Gyeonggi do Korea Tel 82 31 299 5453 Fax 82 31 357 2610 ...

Page 2: ...d functions 2 Installation 12Page 2 1 Installation 2 2 Wiring diagram 2 3 Cautions 3 Cautions Maintenance 17Page 3 1 Cautions for operation 3 2 Cleaning replacement of ion emitters 3 3 Cleaning of fan 4 Settings 21Page 4 1 How to set values 4 2 Explanation on Menu options APPENDIX 23Page 1 Trouble shooting 2 Warranty 2 DONG IL TECHNOLOGY LTD CONTENTS ...

Page 3: ... 24V 10 Input current Max 0 8A Ion emitter pin Tungsten or Titanium Ion balance 10V Typical Decay time Better than 2 0 seconds at 600mm Fan Speed Max Level 5 Air volume Max 4 6 min per Fan Ozone generation Under 0 005ppm Under 0 05ppm Display 7segment Display HV Alarm LED G R Fan Alarm LED G R Green Normal Red Abnormal Manual control Fan Speed Operating frequency Ion balance Auto cleaning PLC Alar...

Page 4: ...lsed AC Auto DC ASF ADMR Pulsed AC Manual DC ASF PDA High Frequency Auto AC DC ASF PDM High Frequency Manual AC DC ASF PDAR High Frequency Auto DC ASF PDMR High Frequency Manual DC A S F D CODE Structure ASF Single Fan Ionizer A Pulsed AC P High Frequency D 120mm Fan Type A Auto pin cleaning M Manual R DC Type _suffix Product lineup Product lineup ...

Page 5: ...5 DONG IL TECHNOLOGY LTD 1 4 Dimensions ...

Page 6: ...asure Condition 1kV 100V Charged plate size 150 x 150 Charged plate Capacitance 20 Ambient conditions 25 45 RH 6 DONG IL TECHNOLOGY LTD 1 5 Performance Relation between Distance and Decay Time Relation between Distance and Decay Time ...

Page 7: ...ts before installation Main body Standard brackets AC power cable 1 800 Ground Wire 1 500 Options Remote controller DC power cable RJ45 CABLE 8Pin PLC PLC RS485 Communications Main body Ground Wire AC power cable RJ45 CABLE 8Pin PLC RS485 communications Remote controller DC power cable O P T I O N S ...

Page 8: ...and functions 8 Front side Control Display operation condition menu and setting value Control on off AC input power Air outlet and front cover Emitter fixing cover Ion emitter Bracket fixing wrench bolt M5 Bracket Rotating plate for cleaning ...

Page 9: ...value Remote Control receiver Output power alarm LED Green Red Shows the state of ion emissions Fan malfunction alarm LED Green Red Shows whether fans are functioning properly or not Menu operation keys Auto pin cleaning key specific product only AC input power on off key Product condition and check point regarding LED ...

Page 10: ...TD 1 7 Parts names and functions Back side AC POWER Connector DC type have no connector DC POWER Connector Be sure to check a diagram page 13 before wiring RJ 45 Connector PLC cable RS485 communication Ground cable connector ...

Page 11: ...TD 1 7 Parts names and functions Bracket Tilt hole Use this hole if you need to adjust angle Height hole Use this hole if you need to adjust height Main body fixing hole Fix a main body to installation place before operation ...

Page 12: ... cause a malfunction In case of using DC power supply be sure to connect the ground wire in DC24V cable included in the package referring the wiring diagram 2 2 The product must be connected to prevent electric shock and guarantee best performance When power is supplied LED is lit on in red and is turn into green within a second From then ions are released to neutralizing static electricity Contro...

Page 13: ...l Green Power Ground DC Power Ground Blue PLC Circuit Fan Alarm Signal Violet Communication TX Signal RS485 Communication RJ45 Cable Wiring DONG IL TECHNOLOGY LTD 2 2 Wiring diagram PIN No Color Connection Usage Black Power Ground DC Power Ground White 24V DC Power Supply 24V DC Power Input Cable 24V DC power input cable wiring 1 Connect Black wire to power ground 2 Connect Red wire to DC 24V ...

Page 14: ...ld ground Connect the orange emitter cleaning and yellow PLC on off cables to PLC 0V which makes PLC work If you open it PLC doesn t work Please refer to the ASF AD PD Series PLC Circuit Diagram above The brown HVPS and blue Fan cables are for an alarm signal Setting Load Set the output current under 100mA DONG IL TECHNOLOGY LTD Warning ...

Page 15: ...n you use a PLC On off function You can only control PLC when a switch is closed You should use non lock type switch when you use a PCL Clean function Auto pin cleaning function is operated repeatedly while switch is closed While PLC Clean Switch on a diagram is closed ions are not generated for safety reasons R C filter on input terminal is connected in parallel to prevent malfunction due to exte...

Page 16: ...entic parts supplied Using improper parts may cause malfunction Be well informed of this instruction before installing or using the product Don t put extraneous materials like metal wire etc near the product for safety Don t move clean or touch the product during operation Remove water and oil from the place where the product is installed and avoid high temperature 50 and high humidity RH 70 Don t...

Page 17: ... this product for any other purpose except for neutralizing static electricity Keep distance from the product during operation and don t breathe for a long time in front of air flow from the product Firmly fix the main body not to fall Install the product beyond children s reach Don t install the product in the place exposed to flame direct ray of the sun or a lot of dusts Be sure to check a groun...

Page 18: ...nt on menu tiP Refer to a detailed setting method on page 4 1 4 2 Using the PLC Auto pin cleaning function is operated repeatedly while switch is closed Refer to a diagram on page 3 2 18 DONG IL TECHNOLOGY LTD 3 2 Cleaning replacement of ion emitters PUSH Please clean ion emitter pins regularly to guarantee the best performance of the product Cleaning period can be different according to the usage...

Page 19: ...p of emitter is damaged When a tip of emitter is seriously damaged or broken product performance is getting worse Replace emitter pins after manual cleaning if required Assemble it in reverse order How to replace emitter pin Do step in manual cleaning method Turn a emitter pin cover counter clockwise to separate Replace a pin Ass y Be sure to assemble that the word Front on cover is on a front sid...

Page 20: ...screws and separate a filter cover case Figure 1 Separate a fan softly to the back side of a product Remove a foreign substance with a compressed air or soft cleaning equipment Figure 2 Assemble it in reverse order A wire can be damaged with excessive assembly and disassembly Figure 1 Figure 2 Warning ...

Page 21: ...Press OK while holding Menu to be down digit Press Menu while holding OK to be up digit Entering right address display SEL on FND Pressing OK display MnU on FND Press OK one more time to enter the main Menu Use or to find a specific menu option that you need or Hold OK for 2 seconds when the panel displays Adr You can see the previous setting value on display Use or to change the value and press O...

Page 22: ...P Setting Emitter Pin Cleaning Period If you set the value YES on menu cleaning cycle is start When cleaning cycle get to end auto pin cleaning function is operate Cleaning cycle can be set daily t01 t30 PAS Setting Password When the password is on you need to enter the old password to enter the main Menu for a new password setup Password can be a three digit number any number between 000 and 999 ...

Page 23: ... red 5 sec later after power connection please contact your dealer Auto pin cleaning function doesn t work Please contact your dealer Fan doesn t work on power Check the value oFF on Ion menu Check the value oFF on Fan menu Fan LED is red and the fan doesn t work Please contact your dealer When you smell something metallic It is natural smell generated when making high voltage When you smell somet...

Page 24: ...ny damage if the product is used in a way different from that is explained in this manual or remade by users arbitrarily 2 Any damage led by improper usage We recommend the installation circumstances in this manual but that is just a recommendation and users are responsible for understanding the product s specification and judgment of suitability of usage 3 Direct or indirect damage led by the pro...

Reviews: