Donaldson UFM-T100H Manual Download Page 8

8

Notes for electrical
connection

Strip the insulation off

6 inches

of the

cable.

  The unit only operates when power is

supplied and 

with the protective

strip connected. 

The installation

must be carried out as per VDE 100

[NEC] .

 Connection values :

/-10%     

50Hz or

/-10%

60Hz or

  24VDC +/-10%

Attention: See also name plate

  Provide an easily accessible means to

cut off the power.

Only use the PG screwed connection

for an installation with a flexible cable.

Remove the PG screwed connection

when using a hose with a screwed

connection. Screw fittings approved

by VDE or UL are to be used here.

US

Condensate flows through the

condensate inlet 

F

 and collects in the

collecting area

 O. 

The membrane is

closed off by the system pressure .

When the moisture sensor detects liquid.

the pressure is released on membrane 

P

which then opens, and the condensate is

driven out by the system pressure. The

Membrane closes before air can escape.

Function

In the heater are line resistance are

installed, that  gives out heat.

The heat is transfer by the conducted

heater on the aluminium housing.

The control of the heater with

temperature sensors is integrated.

One  temperature sensor switches the

heater on when the ambient temperature

is falls under approx.

4

3

°F

.

An other temperature sensor protects the

heater against overheating.  The cut-off

temperature is approx.

140°F

.

  The packing material and the unit

itself and its accessories are

produced from recyclable materials.

  Separating the remaining materials in

an appropriate way helps in the

recycling of materials .

Protection of the
enviroment

Summary of Contents for UFM-T100H

Page 1: ...UFM T100H US ES CA TM Power Test Alarm...

Page 2: ...A B C D H L P O Q R U V W X N M G I J K S T E F...

Page 3: ...Test Power Alarm 9 3 4 Test Power Alarm 1 5 2 Powe r Alarm Test Test Power Alarm 6 7 8 Powe r Ala rm Test 12 Powe r Alarm Test Powe r Alarm Test 10 11 max 40 psi US...

Page 4: ...al free contact max 230V AC relay Programmer connection Alarm connection potential free contact 1 3 2 2 3 1 View on plug View on socket Diode suppressor max 92 mA max 92 mA Interference protection con...

Page 5: ...US 6 10 Warranty 11...

Page 6: ...unit through these operation instructions It is essential that you follow these safety notes and this information in order to ensure trouble free operation of the unit All safety information in always...

Page 7: ...and leads to functional problems with the unit 3 Ensure that each pressure vessel has its own drain Make sure that the chosen power supply matches with the power supply of the rating on the name plate...

Page 8: ...rane is closed off by the system pressure When the moisture sensor detects liquid the pressure is released on membrane P which then opens and the condensate is driven out by the system pressure The Me...

Page 9: ...existing thread US Error display LED flashes An alarm message is given if the potential contact was connected Cause Sensor damp or unit flooded Reaction of the unit The potential free contact opens Th...

Page 10: ...within the permissible technical parameters not authorised constructional changes were made to the unit or if parts of the unit that may not be opened were dismantled Spare parts Set of replacement pa...

Page 11: ...y defects in material or workmanship in accordance with Donaldson Company Inc Warranty Policy and Procedures Donaldson Company Inc retains the sole option to accept return of the goods with freight pa...

Page 12: ...s r serve de modifications technicques Alteraciones t cnicas reservadas UFM T100H_US R03 2008 06 Donaldson Company Inc Compressed Air Gas P O Box 1299 Minneapolis MN 55440 1299 U S A Tel 800 543 3634...

Reviews: