background image

6

US

Functional elements

For your saftey

A

Cover screws Pozidrive 1; 

0.74 ft lbf

B

Cover with heater

C

 LED

Light On:

On

Light Flashing:  Error

D

Test button

E

Cover

F

Fixing screw

G

Ribbon cable

H

Inlet opening

G

1” ISO 228/1

I

Potential-free contact 3,4

J

Power supply , contact 1,2

Attention  24VDC-Version !

Contact 1

+24VDC

Contact 2

   0 VDC

K

Earthing connection, PE

L

Key area

2"

M

   M16x1,5

screw connection for potential-

free contact 3,4 (option)

N

M16x1,5

 screw connection for

power supply 1,2

O

Collecting area seal

P

Condensate collecting area

Q

Membrane

R

Drain plug

S

Replacement parts set
(without adapter T)

T

Membrane adapter

U

Fastening holes for attachement to a
console (self-tapping screws,
DIN7990; D5,5mm; Lmax 20mm)

V

Screws (

4

x) long

Torx

®

;

19.2 ft lbf

W

Screws (2x) short

Torx

®

;

 19.2 ft lbf

X

Drain and drain adapter

You as operator / user of the unit should

make yourself familiar with the function,

installation and start-up of the unit

through these operation instructions.
It is essential that you follow these

safety notes and this information in

order to ensure trouble-free operation of

the unit.
All safety information in always intended

to ensure your personal safety

  The pressure and temperature of the

medium must match witch the details

given on type plate of the unit.

  Installation work may only be carried

out by trained and experienced

specialists.

  Disconnect the power supply when

carrying out electrical work.

  Wear protective glasses, when

working with media under pressure.

  Risk of explosion ! It is not permitted

to use this unit in areas at risk of

explosion or with explosive or

inflammable media.

  It is forbidden to carry out any kind of

work on the pressure vessels and

piping this covering welding,

constructional changes, installation

work, etc. Breaking this rule means

extreme danger for you.

  Clean the piping before carrying out

the installation work.

  Make a visual check before the initial

start-up. There must be no external

damage visible.

  Depressurize the system before

carrying out the installation work.

  Use the unit for appropriate purpose!

Summary of Contents for UFM-T100H

Page 1: ...UFM T100H US ES CA TM Power Test Alarm...

Page 2: ...A B C D H L P O Q R U V W X N M G I J K S T E F...

Page 3: ...Test Power Alarm 9 3 4 Test Power Alarm 1 5 2 Powe r Alarm Test Test Power Alarm 6 7 8 Powe r Ala rm Test 12 Powe r Alarm Test Powe r Alarm Test 10 11 max 40 psi US...

Page 4: ...al free contact max 230V AC relay Programmer connection Alarm connection potential free contact 1 3 2 2 3 1 View on plug View on socket Diode suppressor max 92 mA max 92 mA Interference protection con...

Page 5: ...US 6 10 Warranty 11...

Page 6: ...unit through these operation instructions It is essential that you follow these safety notes and this information in order to ensure trouble free operation of the unit All safety information in always...

Page 7: ...and leads to functional problems with the unit 3 Ensure that each pressure vessel has its own drain Make sure that the chosen power supply matches with the power supply of the rating on the name plate...

Page 8: ...rane is closed off by the system pressure When the moisture sensor detects liquid the pressure is released on membrane P which then opens and the condensate is driven out by the system pressure The Me...

Page 9: ...existing thread US Error display LED flashes An alarm message is given if the potential contact was connected Cause Sensor damp or unit flooded Reaction of the unit The potential free contact opens Th...

Page 10: ...within the permissible technical parameters not authorised constructional changes were made to the unit or if parts of the unit that may not be opened were dismantled Spare parts Set of replacement pa...

Page 11: ...y defects in material or workmanship in accordance with Donaldson Company Inc Warranty Policy and Procedures Donaldson Company Inc retains the sole option to accept return of the goods with freight pa...

Page 12: ...s r serve de modifications technicques Alteraciones t cnicas reservadas UFM T100H_US R03 2008 06 Donaldson Company Inc Compressed Air Gas P O Box 1299 Minneapolis MN 55440 1299 U S A Tel 800 543 3634...

Reviews: