Donaldson Company, Inc.© 1998
17
4.0
4.0
4.0
4.0
4.0 OPERATION
OPERATION
OPERATION
OPERATION
OPERATION
Turn the unit on/off as required for your
operation. When the airflow becomes low, turn
the unit off, wait until the fan runs down and the
shake cycle is complete and then restart the unit.
The RVS fan must operate for at least 30 seconds
to reset the shake cycle control logic.
5.0
5.0
5.0
5.0
5.0 ROUTINE MAINTENANCE
ROUTINE MAINTENANCE
ROUTINE MAINTENANCE
ROUTINE MAINTENANCE
ROUTINE MAINTENANCE
5.1
5.1
5.1
5.1
5.1 Dust Drawer Models
Dust Drawer Models
Dust Drawer Models
Dust Drawer Models
Dust Drawer Models
Empty the collector dust drawer periodically or
whenever it becomes two-thirds full. Also remove
any dust that has settled to the bottom of the dust
compartment. Shut off the collector fan before
emptying the dust drawer.
5.2
5.2
5.2
5.2
5.2 Hopper Models
Hopper Models
Hopper Models
Hopper Models
Hopper Models
1. The hopper is not for dust storage. Empty it
periodically as necessary to keep the dust in
the hopper at a minimum. If a drum or pail is
used, empty it when two-thirds full. Shut off
the collector before emptying the drum or pail.
2. If the unit has a pail with a gate, close the gate
and empty the pail. Reinstall the pail and open
the gate. The collector fan does not need to be
shut off if this procedure is followed.
3.0
3.0
3.0
3.0
3.0 ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
ELECTRICAL
1. Make electrical connections to the disconnect
switch*, fan starter*, fan motor and control
box. See Figure 16—Electrical Wiring Diagram
and reference 2SG-40533-00 Single Filter
Cleaning Mechanism Print. Fan access is
through the top door of the cabinet.
* Customer supplied
2.
Start the fan motor and check fan for proper
rotation
as indicated by the arrow on the fan
housing. Proper rotation is extremely
important. Even if the fan is running in the
wrong direction, it will deliver approximately
40% of its rated air volume on the Single RVS-
5/10/15. If the rotation is incorrect, reverse any
two leads (3 phase only) on the output side of
the fan motor starter.
Disconnect and lockout all electrical
power to the collector before
performing any service work.
All electrical work must be done
by a qualified electrician according
to local codes.
• Check the air exhaust outlet at
the top of the collector to be
sure that it is not blocked or
that material is not stored over
the exhaust opening.
• Stand clear of the fan exhaust
during the rotation check.
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
All electrical controls should be
remote mounted on collectors with
explosion vents.
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION