13
Donaldson Company, Inc.
If the collector was supplied with an electrical
control panel, the wiring diagram supplied with
the control panel takes precedence over the
general diagrams shown in this manual.
Cleaning Mechanism Assembly and
Adjustment
1. The gear reducer ships prefilled with lubricant.
Remove the pipe plug and install the breather.
2. Remove the plastic exhaust-port plug from the
bottom of the solenoid valve.
3. Wire the motor to a customer-supplied motor starter
with overload and short circuit protection.
4. Remove all shipping restraints from manifold arms
and shipping braces from the cleaning system and
cleaning system support frame.
Electrical installation, service,
or maintenance work must
be performed by a qualified electrician and
comply with all applicable national and local
codes.
Turn power off and lock out all power before
performing service or maintenance work.
Do not install in classified hazardous
atmospheres without an enclosure rated for
the application.