background image

This is the safety alert symbol.  It is used to alert you to potential personal injury hazards.  
Obey all safety messages that follow this symbol to avoid possible injury or death.  

This manual is property of the owner. Leave with the unit when set-up and start-up are complete. Donaldson Company reserves the right to 

change design and specifications without prior notice. 
Illustrations are for reference only as actual product may vary.

Trunk 2000™

T-2000

Installation and Operation Manual

Installation, Operation, and Service Information

IOM 4078300 (ENG)

Revision 7

English

Master Language

Summary of Contents for Torit AIRPLUS Trunk 2000 T-2000

Page 1: ...s property of the owner Leave with the unit when set up and start up are complete Donaldson Company reserves the right to change design and specifications without prior notice Illustrations are for re...

Page 2: ...on assumes no responsibility or liability for the suitability of any fire and or explosion mitigation strategy or any items incorporated into a collector as part of an owner operators hazard mitigatio...

Page 3: ...Inc Contents Description 1 Purpose and Intended Use 1 Rating and Specification Information 2 Operation 3 Inspection on Arrival 4 Installation Codes and Procedures 4 Installation 4 Foundations or Suppo...

Page 4: ...it Trunk 2000 is used to filter weld fume dust and particulate from plant sources and to recirculate clean air back to the workplace Ceiling hung or wall supported the compact size coupled with large...

Page 5: ...Trunk 2000 T 2000 2 All Collectors Compressed air maximum psig 90 psig 1 11 scf pulse Power and controls 115 VAC Rating and Specification Information Front View Typical Side View...

Page 6: ...gm valve to send a pulse of compressed air through the filter elements from the inside outward removing the dust from the outside of the filter elements The dust then falls into the hopper At the end...

Page 7: ...compromise collector performance Inspect collector to ensure all hardware is properly installed and tight prior to operating collector Installation Use proper equipment and adopt all safety precautio...

Page 8: ...e suspended or hung from overhead supports The supports must be adequate to carry the live load of the collector and installed to reduce sway or vibration to the collector Provide clearance from heat...

Page 9: ...and nuts typical Collector Suspension Both the 12V and 115V power to the collector are supplied from the Torit control box The control box can be mounted where it is convenient to the user When final...

Page 10: ...ting must be used See collector s rating plate for required voltage An electric disconnect switch having adequate amp capacity shall be installed in accordance with Part IX Article 430 of the National...

Page 11: ...nnect switch incoming power supply blower motor starter optional pulse control switch 1TGS solid state timer air regulator bleed type air filter safety exhaust valve automatic condensate valve air sup...

Page 12: ...ol board s preset OFF time At the end of the OFF time the control will energize a solenoid to provide the cleaning pulse for one segment of filter elements and then step to the next segment This cycle...

Page 13: ...ied and turned ON and OFF by the 200 watt maximum load per output solid state switch Pulse ON Time Factory set at 100 milliseconds Do not adjust pulse ON time unless the proper test equipment is avail...

Page 14: ...instructions on the motor s nameplate To reverse rotation three phase power supply Switch any two leads on the motor junction box Do not interchange a power lead with the ground wire Severe personal...

Page 15: ...ir manifold Filter Removal and Installation Use proper safety and protective equipment when removing contaminants and filters Dirty filters may be heavier than they appear Use care when removing filte...

Page 16: ...ure a positive filter gasket seal 7 Check for an accumulation of dust in the storage area and empty as necessary suspension yoke filter cartridge extraction arm filter access cover Filter Removal and...

Page 17: ...nstallation 2 Sweep or brush hopper walls 3 Replace filters and close filter access covers securely See Filter Removal and Installation 4 Remove the dustpans and dispose of dust properly Empty and cle...

Page 18: ...ushings B Bushing barrel and Product bore are tapered C Bushing cap screws D Bushing barrel is split except idler bushings E Removal holes are threaded installation holes are not Hub of blower wheel o...

Page 19: ...the extraction arms to the unit See Extraction Arm Installation and Operation Manual for instructions Do not over tighten thread forming screws 4 Remove lifting equipment 1 4 in diameter rope type sea...

Page 20: ...plenum and the low pressure tap is located in the clean air plenum 1 Choose a convenient accessible location on or near the collector for mounting that provides the best visual advantage 2 Plug the pr...

Page 21: ...Trunk 2000 T 2000 18 This Page Intentionally Left Blank...

Page 22: ...collector for mounting that provides the best visual advantage 2 Mount the gauge to the remote panel or door using the mounting ring retaining ring and four 6 32 x 1 1 4 in screws Do not tighten screw...

Page 23: ...L1 HI LO C NO NC NC NO C C NO NC NC NO C pressure switch L1 L2 1 2 3 sol com timer board transformer blower fan starter Photohelic gauge jumper jumper stop start 1M 115 V Photohelic Gauge Wiring Photo...

Page 24: ...ough the filters creating a pressure drop The Delta P Controller measures the pressure drop and provides a visual display in inches water gauge or metric SI collectors of daPa Filter Cleaning When the...

Page 25: ...f daPa Filter Cleaning The Delta P Plus Controller offers three filter cleaning options 1 Differential Pressure Cleaning DFF When the pressure drop across the filters reaches the Controller s High Pre...

Page 26: ...arge quantity of water in the dust collector when activated Provide adequate drainage to remove water Excess water weight can cause the leg structure to collapse Consult with local authorities when in...

Page 27: ...not installed on T 2000 Install the extraction arm to the T 2000 inlet panel See Extraction Arm Installation and Operation Manual Clean air outlet discharging dust Filters not installed correctly See...

Page 28: ...ment See Solid State Timer and Solid State Timer Wiring Diagram Damper control in extraction arm is closed Check that the damper control s are open The damper handle should be located in line with the...

Page 29: ...door to outdoor Recalibrate with the pressure tubing attached as described in the Delta P Maintenance Manual Delta P Controller ON but cleaning system does not start Pressure tubing disconnected ruptu...

Page 30: ...27 Donaldson Company Inc Date Service Performed Notes Service Notes...

Page 31: ......

Page 32: ...or product misapplication Donaldson also makes no warranty whatsoever as to any goods manufactured or supplied by others including electric motors fans and control components After Donaldson has been...

Reviews: