Installation, Operation and Maintenance manual
4
Downflo
®
Evolution
GENERAL SAFETY REQUIREMENTS
This manual contains specific precautionary statements relative to worker safety in
appropriate sections. To avoid dangerous situations we give you the following advice:
Refers to special information on how to use the dust collector most
efficiently.
Refers to special information directed towards preventing damage.
Refers to special information designed to prevent injury or extensive
damage.
The collector should be stored as supplied. Remove packaging for installation
only.
For the purposes of storage:
•
Collector with specification for inside use = IP50
•
Collector with specification for outside use = IP54
The dust collector has been built in accordance with state-of-the-art standards
and recognised safety rules. Nevertheless if not handled carefully it may put
people at risk and also cause damage.
The dust collector should be used only when it is in technically perfect
condition, in accordance with its designated use and the instructions set out
in the operation manual. Any functional disorders, especially those affecting
safety, should therefore be rectified immediately.
Ensure proper training is given to operators before start-up. The dust collector
is designed exclusively for use within the scope of delivery, and in accordance
with drawing(s) and the specification sheet.
Do not put lit cigarettes or any burning object into the hood or ducting of any
dust collection system.
Regular maintenance is important for a good performance of your dust collector.
A prudent user of Donaldson Torit equipment should consult and comply with
all relevant Fire Codes and/or other appropriate codes when determining the
location and operation of dust collection equipment.
A hand-operated supply disconnecting device is necessary for each incoming
electrical supply in accordance with EN 60204-1.
To prevent accidents the access to the fan impellor must not be possible during
operation. Refer to EN 294.
Disconnect all power before servicing. All electrical work must be done by a
qualified electrician according to local codes.
All exposed conductive parts of the electrical equipment and the dust collector
shall be connected to the protective bonding circuit (refer to EN 60204-1).