WSO Mist Collector, WSO M
16
2. Make the wiring connections to the fan motor
according to the wiring diagram located inside the
control box and the instructions on the motor decal.
All electrical components must
be sized for the supply voltage
and motor horsepower. See Motor Starter
Wiring.
3. Turn the fan-motor ON then OFF and check for proper
rotation by removing the inspection cover on the top
of the WSO M and viewing the wheel rotation.
To reverse rotation, single-phase power supply:
Follow manufacturer’s instructions on the motor’s
nameplate.
To reverse rotation, three-phase power supply:
Turn electrical power OFF at source and switch any
two leads on the motor junction box.
Do not interchange a power lead
with the ground wire. Severe
damage or personal injury may result.
exhaust pack
fan motor
junction box
fan wheel
inspection cover
Fan Blower