Donaldson Company, Inc.
30
Problem
Probable Cause
Remedy
Insufficient airflow
continued
Lack of compressed air
Check that a minimum of 90-psig is available.
See Compressed Air Supply section.
Pulse cleaning not energized
Use a voltmeter to check supply voltage to the
timer board. Check and replace the fuse on the
timer board if necessary. See Solid-State Timer
section.
Dust storage area overfilled
or plugged
Clean out dust storage area. See Dust Disposal
section.
Pulse valves leaking
compressed air
Lock out all electrical power to the unit and
bleed the compressed air supply. Check for
debris, valve wear, pneumatic tubing fault, or
diaphragm failure by removing the diaphragm
cover on the pulse valves. Check for solenoid
leaks or damage. If pulse valves or solenoid
valves and tubing are damaged, replace.
Solid-State Timer failure
Using a voltmeter, check supply voltage to the
timer board. Check and replace the fuse on the
timer board if necessary. If the fuse is good and
input power is present, but output voltage to the
solenoid valves is not, replace the timer board.
See Solid-State Timer section.
Solid-State Timer
out of adjustment
See Solid-State Timer Wiring Diagram.