background image

Downflo Oval, DFO 2-8 to 4-128

 4

Inspection on Arrival

1.  Inspect collector upon delivery.
2.  Report any damage to the delivery carrier.
3.  Request a written inspection report from the Claims 

Inspector to substantiate any damage claim.

4.  File claims with the delivery carrier.
5.  Compare collector received with description of 

product ordered.

6.  Report incomplete shipments to the delivery carrier 

and your Donaldson Torit representative.

7.  Remove crates and shipping straps. Remove loose 

components and accessory packages before lifting 

collector from truck.

8.  Check for hardware that may have loosened during 

shipping.

9.  Use caution removing temporary covers.

Installation Codes and Procedures

Codes may regulate recirculating 

filtered air in your facility. 

Consult with the appropriate authorities 

having jurisdiction to ensure compliance 

with all national and local codes regarding 

recirculating filtered air.

Safe and efficient operation of the collector depends on 

proper installation. 
Authorities with jurisdiction should be consulted 

before installing to verify local codes and installation 

procedures. In the absence of such codes, install 

collector according to the National Electric Code, 

NFPA No. 70-latest edition and NFPA 91 (NFPA 654 if 

combustible dust is present).
A qualified installation and service agent must complete 

installation and service of this equipment.
All shipping materials, including shipping covers, must 

be removed from the collector prior to or during collector 

installation.

Failure to remove shipping 

materials from the collector will 

compromise collector performance.

Inspect collector to ensure all hardware is properly 

installed and tight prior to operating collector.

Do not set compressed-air 

pressure above 100-psig as 

component damage can occur.
All compressed air components must be sized 

to meet the system requirements of 90-100-psig 

supply pressure.
The compressed-air supply must be oil 

and moisture free. Contamination in the 

compressed air used to clean filters will result 

in poor cleaning, cleaning valve failure, or poor 

collector performance.
Purge compressed air lines to remove 

debris before connecting to the collector’s 

compressed air manifold.

Installation

Use proper equipment and adopt 

all safety precautions needed for 

servicing equipment.
Electrical service or maintenance work must 

be performed by a qualified electrician and 

comply with all applicable national and local 

codes.
Turn power off and lock out all power before 

performing service or maintenance work.
Do not install in classified hazardous 

atmospheres without an enclosure rated for 

the application.
Turn compressed air supply OFF, bleed and 

lock out lines before performing service or 

maintenance work.
Site selection must account for wind, seismic 

zone, and other load conditions when selecting 

the location for collectors.
Codes may regulate acceptable locations for 

installing dust collectors. Consult with the 

appropriate authorities having jurisdiction to 

ensure compliance with all national and local 

codes regarding dust collector installation.
Collectors must be anchored in a manner 

consistent with local code requirements. 

Anchors must be sufficient to support dead, 

live, seismic, and other anticipated loads.
Consult a qualified engineer for final selection 

of anchorage.

Summary of Contents for DFO 2-12

Page 1: ...on and Service Information IOM 9343601 ENG Revision 15 English Master Language This manual contains specific precautions related to worker safety The hazard alert image denotes safety related instruct...

Page 2: ...ipment This manual has been supplied to assist with the installation operation and maintenance for the collector purchased Please read the manual before installing operating or performing maintenance...

Page 3: ...nstallation 13 Electrical Wiring 13 Solid State Timer Installation 15 Solenoid Connection 15 Timer and Solenoid Specifications 15 Preliminary Start Up Check 17 Maintenance Information 18 Operational C...

Page 4: ...r control Donaldson does not provide engineering consulting services related to process or dust hazard analyses or code and standard compliance Complying with applicable codes and standards and managi...

Page 5: ...pical applications include abrasive blasting grinding pharmaceuticals powder paint applications sand handling and welding Each application is different and selecting the correct filter for the applica...

Page 6: ...The cleaning sequence starts at the top filter row and continues down through each module Remove inspect or change the cartridges from outside the collector by removing the filter access cover and sl...

Page 7: ...collector will compromise collector performance Inspect collector to ensure all hardware is properly installed and tight prior to operating collector Do not set compressed air pressure above 100 psig...

Page 8: ...t a qualified engineer for final selection of foundation or support framing The collector is suitable for either indoor or outdoor installations Reference the Rating and Specification Information Site...

Page 9: ...ift collector over leg and hopper assembly and lower slowly 8 Secure with bolts washers and nuts supplied 9 Remove crane 10 Apply sealant to hopper cabinet seam angle not to exceed 30 from vertical mi...

Page 10: ...classified hazardous atmospheres without an enclosure rated for the application Turn compressed air supply OFF bleed and lock out lines before performing service or maintenance work Field Assembly Mod...

Page 11: ...Downflo Oval DFO 2 8 to 4 128 8 inlet deflector plate see Detail E yoke see Detail F clean air plenum outlet cover see Detail H filter access cover see Detail A dirty air plenum Module Assembly...

Page 12: ...he clean air plenum See Detail H Do not tighten hardware at this time 4 Adjust jam nut against the filter cartridge panel Have one person hold the yoke in position as shown in Detail F while another p...

Page 13: ...in hex nut 3 8 x 1 1 4 in bolt 3 8 in flat washer inlet deflector panel Detail F yoke Detail G 3 8 in hex nut venturi 3 8 in flat washer 3 8 in lock washer 3 8 in hex jam nut yoke shoulder filter car...

Page 14: ...on over anchor bolts Secure each leg pad to the foundation anchor bolts with customer supplied flat washers and nuts Do not tighten hardware at this time Tighten all hardware before removing crane to...

Page 15: ...DFO 3 72 and 4 96 8 module DFO 4 128 9 module for larger collectors supplied with extended dirty air plenum and air management module 10 module for larger collectors supplied with extended dirty air p...

Page 16: ...f 90 100 psig supply pressure The compressed air supply must be oil and moisture free Contamination in the compressed air used to clean filters will result in poor cleaning cleaning valve failure or p...

Page 17: ...d type air filter automatic condensate valve air supply line 1 2 3 4 safety exhaust valve blower 1 solid state timer 2 blower motor starter 3 power supply disconnect switch 4 Magnehelic gauge customer...

Page 18: ...imer Solenoid Connection The collector is equipped with electric solenoid valves typically 120V that controls the pulse cleaning valves which in turn clean the filters Solenoid enclosures are mounted...

Page 19: ...to clean one or more filters every 10 seconds during a cleaning cycle Do not increase supply pressure above 100 psig as component damage can occur 1FU 2FU 3FU 208 230V 60 Hz 3Ph IL1 IL2 IL3 1M 1OL 1T...

Page 20: ...motor junction box Do not look into fan outlet to determine rotation View the fan rotation through the back of the motor Check that the exhaust plenum is free of tools or debris before checking blowe...

Page 21: ...ice or maintenance work Turn compressed air supply OFF bleed and lock out lines before performing service or maintenance work Do not operate with missing or damaged filters Filter Removal and Installa...

Page 22: ...ets clean and replace covers by attaching cover to yoke hook and firmly latching cover handle Replaced access covers carefully by securing them using the handle provided Keep fingers away from the sea...

Page 23: ...ver handle Optional and Bag In Bag Out Filter Access Cover Removal Top View Filter Access Cover Removal Side View latched unlatched removal access cover yoke latched unlatched yoke access cover hook a...

Page 24: ...flow through the collector Lack of a control damper or VFD will shorten filter life Optional Equipment blower and motor assembly sealant sealant side power adapter Side Mount Fan Blower Side MountTBI...

Page 25: ...acket For complete information see the most current version of the TBI or TRB Fan Installation Operation and Maintenance manual Typical Side and Top Mount Silencer and Damper Installation power pack p...

Page 26: ...8 in gasket spacer between the hopper flange and slide gate as shown 2 Attach the drum pack and slide gate to the hopper flange using 3 8 16 bolts washers and hex nuts 3 Attach the drum cover to the...

Page 27: ...pe sealant 3 8 16 bolt 3 8 in flat washer 3 8 in lock washer 3 8 16 hex nut adapter 55 Gallon Drum Pack without Slide Gate hopper flange drum cover slide gate optional latch customer supplied 55 gallo...

Page 28: ...Turn power off and lock out all power before performing service or maintenance work Keep hands feet and loose clothing away from both inlet and outlet openings to avoid injury or damage when valve is...

Page 29: ...wo self drilling screws 5 Thirty five feet of plastic tubing is supplied and must be cut in two sections Connect one section of tubing from the gauge s high pressure port to the pressure fitting locat...

Page 30: ...rts Tighten screws 3 On the back of the gauge remove four 6 32 x 5 16 in screws and plastic enclosure Set aside Add two jumper wires supplied by customer Remove the jumper from the pressure switch loc...

Page 31: ...x 1 4 in mounting screws mounting bracket static pressure tee 1 8 in NPT x 90 elbow 1 8 in NPT adapter 1 8 in NPT adapter 3 8 in flat washer dirty air plenum pressure tap location 1 8 in NPT adapter 1...

Page 32: ...through the filters creating a pressure drop The Delta P Controller measures the pressure drop and provides a visual display in inches water gauge or metric SI units of daPa Filter Cleaning When the p...

Page 33: ...e Delta P Plus Controller offers three filter cleaning options 1 Differential Pressure Cleaning DFF When the pressure drop across the filters reaches the Controller s High Pressure On setpoint the Con...

Page 34: ...ing 4 Install the top of the silencer and attach silencer to base using the supplied hardware 5 Loosen the wing nut on the damper and adjust from 30 to 50 closed collector sealant flat washer 3 8 16 x...

Page 35: ...side only Complete installation and assembly instructions are shipped with the platform Dropping the platform can result in personal injury or property damage Secure the platform assembly to the crane...

Page 36: ...dirty air plenum although front or side locations limit the area to 36 x 36 in Air Management Module The air management module is used in applications involving heavy grain loading large or abrasive...

Page 37: ...the basic kit plus a heat cable to deliver heat to the large pulse valves This kit is customer installed and detailed installation instructions are provided 1 Install the power connection kit on the h...

Page 38: ...ng of an explosion must be safely directed outdoors away from areas occupied by personnel to reduce risk of personal injury and or property damage The risk of personal injury and or property damage ca...

Page 39: ...operly Check airflow in duct Adjust damper control until proper airflow is achieved and the blower motor s amp draw is within the manufacturer s rated amps Electrical circuit overload Check that the p...

Page 40: ...and input power is present but output voltage to the solenoid is not replace the timer board See Solid State Timer Installation Solid State timer out of adjustment See Solid State Timer and Solid Sta...

Page 41: ...elta P arrow keys do not work Improper operation Press and hold one of the three setpoint keys to use arrow keys Programming keys disabled Remove the Program Disable jumper from Terminals 3 and 4 on T...

Page 42: ...____________ Collected Dust _________________________________________________________________________ Dust Properties Kst_______________Pmax______________MIE____________MEC_________________ Accessorie...

Page 43: ...e foregoing warranty on services Products manufactured by a third party Third Party Product may constitute contain be contained in incorporated into attached to or packaged together with the goods Buy...

Page 44: ...e Many factors beyond the control of Donaldson can affect the use and performance of Donaldson products in a particular application including the conditions under which the product is used Since these...

Reviews: