![Donaldson Torit 252LP Installation And Operation Manual Download Page 22](http://html1.mh-extra.com/html/donaldson-torit/252lp/252lp_installation-and-operation-manual_2520686022.webp)
22
Donaldson Company, Inc.
1.
Open filter access door into the clean air side.
2.
From the clean-air plenum, carefully insert the snap-in filter bag through the tube sheet with the closed end oriented
downward.
3.
Snap the bag in place with the tube sheet between the upper and lower rings on the filter bag collar.
4.
Lower the filter cage into the bag. If the bag section is resting on the ground, the cages will not drop (seat) completely at this
time. When the dirty air plenum is lifted into place, the cages will drop to the correct position (fully seat).
5.
Repeat steps 3-4 for all remaining filter bags and cages.
Note: The cleaning arm will need to be manually rotated to access some bags.
6. Once all bags are installed, ensure the cleaning arms rotate smoothly.
7.
Close the filter access door.
1
2
4
3
Filter Bag and Cage Installation
filter bag
filter bag
upper ring
filter cage
tube sheet
tube sheet
lower ring
cage
Electrical installation, service, or maintenance work must be performed by a qualified electrician and comply with all
applicable national and local codes.
This equipment may start or stop unexpectedly from a remote location.
Turn power off and lock out all power before performing service or maintenance work.
The appropriate wiring schematic and electrical rating must be used. See collector’s rating plate for required voltage.
Do not install in classified hazardous atmospheres without an enclosure rated for the application.
Electrical Wiring
Filter Bag and Cage Installation