6
TECHNICAL CHARACTERI
TECHNICAL CHARACTERI
TECHNICAL CHARACTERI
TECHNICAL CHARACTERISTICS
STICS
STICS
STICS
MODEL
MODEL
MODEL
MODEL
HTP 10
HTP 10
HTP 10
HTP 100
00
0----150
150
150
150 HTP 130
HTP 130
HTP 130
HTP 130----200
200
200
200
DHW total volume
L
100
130
Pellet storage capacity
Kg
150
200
Max. working pressure of tank
bar
7
Max. storage temperature
ºC
80
Max. primary temperature
ºC
85
Max. primary working pressure
bar
3
Weight empty
Kg.
90
110
Weight full
Kg.
340
440
Continuous flow L/h
∆
30 ºC
Q
p
1m
3
/h
683
733
Peak flow L/10min
∆
30 ºC
Q
p
1m
3
/h
252
302
Domestic hot water test operating conditions:
−
Boiler power: 25 kW
−
Domestic water inlet temperature: 15°C,
−
DHW temperature: 45°C,
−
Primary hot water temperature: 80°C,
−
Storage temperature: 60°C
7
77
7
CIRCULATING PUMP STA
CIRCULATING PUMP STA
CIRCULATING PUMP STA
CIRCULATING PUMP STATUS CODE
TUS CODE
TUS CODE
TUS CODES
SS
S
The high efficiency pumps of the HTP
HTP
HTP
HTP deposit tanks include a Led (light) which displays their status.
PUMP
PUMP
PUMP
PUMP
LIGHT
LIGHT
LIGHT
LIGHT
DESCRIPTION
DESCRIPTION
DESCRIPTION
DESCRIPTION
STATUS
STATUS
STATUS
STATUS
CAUSE
CAUSE
CAUSE
CAUSE
SOLUTION
SOLUTION
SOLUTION
SOLUTION
It is lit green
The pump is
functioning
The pump operates
according to its
setting
Standard functioning
1. Low voltage
U<160 V
or
Excess voltage
U>253 V
1. Check the
power
supply
195 V<U<253 V
It flashes
red/green
The is ready for
service but is not
functioning
The pump will start
up again
automatically once
the error has been
solved
2. Excess temperature
of the module: the
temperature of the
motor is too
high
2. Check the
room
temperature and that
of the fluid
Flashes red
The pump is out of
order
The pump is stopped
(blocked)
The pump does not start
up automatically.
Change the pump. Please
contact your nearest
official technical
assistance service to have
it replaced
1. The pump is not
connected to the power
supply
1. Check the
connection of the cable
2. The LED is faulty
2. Check if
the pump works
Light off
There is no power
supply
The electrical system
is not receiving
power supply
3. The electrical system is
faulty
3. Change the
Pump. Change the
pump. Please contact
your nearest official
technical assistance
service to have it replaced