19
EN
Fix the motor in place, bolting the sliding flange
(7)
on the
motor in place with the bolts
(8)
and washers
(9)
.
Fix the outer compressor drawer box in place using
the latches
(16)
.
Brown
Blue
Yellow
Green
Electrically connect the motor, connecting the hose
(2)
to terminals
N
and
9
of the boiler terminal strip
(J2)
. (See
electrical diagram in boiler manual).
Fit the springs
(22)
to the side of the boiler, to hold the ash
drawer transportation handle
(23)
in place.
Fix the motor case
(1)
to the rear of the boiler,
inserting the hooks into the holes.
IMPORTANT:
To ensure the boiler burner functions correctly, the ash drawer lid and the coupling
between the lid and the inner compressor drawer must be hermetically sealed. You should regularly
check the state of the seals for this purpose and replace them with new ones if they are worn.