Ash Compressor Drawer
18
EN
11
INSTALLATION INSTRUCTIONS
Unscrew the four bolts and remove the outer cover from the
rear of the boiler.
Remove the two nuts and take out the inner cover
and the seal.
Remove the top and bottom doors from the boiler. Remove
the manual ash drawer and fit the threaded supports
(19)
to
the ash drawer door frame.
Slot the inner compressor drawer
(15)
into the
boiler, place the closing support
(12)
and fix it in
place tightening the screws
(11)
.
Fit the motor support
(10)
to the rear of the boiler together
with the insulating gasket
(28)
, ensuring the shaft is centred
as correctly as possible in the hole in the gasket.
Insert the motor shaft onto the worm screw shaft,
ensuring the flat sides of both shafts coincide (turn
the worm screw shaft
(13)
for this purpose if
necessary), as shown in the figure.