background image

 

 

 

7

3.2.1

 

Equipment / options 

Although  Sanit  units  are  equipped  with  all  the  necessary  components  for  functioning,  DOMUSA 
TEKNIK offers several optional components for cases in which special features are required. 

3.2.2

 

Cathodic protection 

If  the  chloride  concentration  in  the  domestic 
hot  water  is  higher  than  250  mg/l,  we 
recommend  installing  a  cathodic  protection 
inside  the  storage  heater  to  avoid  premature 
wear  to  the  hot  water  tank. 

DOMUSA  TEKNIK

 

optionally  supplies  a  suitable  electronic 
cathodic  protection  for  its  range  of  storage 
heaters. To install it, carefully read the assembly 
instructions  supplied  with  the  cathodic 
protection. 

 

Figure 1

3.2.3

 

Electrical element 

All  Sanit  hot  water  tanks  have  a  socket  for 
connecting  an  electrical  element. 

DOMUSA 

TEKNIK

  optionally  supplies  three  elements,  of 

1.5,  2.5  and  3.5  kW.  To  install  them,  carefully 
read  the  assembly  instructions  supplied  with 
the elements. 

 

 

Figure 2 

3.2.4

 

18L DHW expansion tank 

Due  to  the  increase  in  the  temperature  of  the 
hot water stored, the pressure in the hot water 
tank increases, and 

DOMUSA TEKNIK

 therefore 

optionally  offers  this  DHW  compensation  tank 
for  the  Sanit  500,  750  and  1000  models.  To 
install  the  tank,  carefully  read  the  assembly 
instructions supplied with it. 

 

 

Figure 3 

 

Summary of Contents for Sanit S 1000

Page 1: ...INSTALLATION AND OPERATING INSTRUCTIONS SANIT S 500 SANIT S 750 SANIT S 1000 SANIT S 1000 SBH ...

Page 2: ... given to the user Read the warnings and recommendations in the manual carefully as they contain important information on the safety use and maintenance of the installation These hot water tanks are to be installed by skilled personnel only in accordance with the legislation in force and following the manufacturer s instructions The start up of these hot water tanks and any maintenance operations ...

Page 3: ... 2 1 Equipment options 7 3 2 2 Cathodic protection 7 3 2 3 Electrical element 7 3 2 4 18L DHW expansion tank 7 3 2 5 1 dielectric sleeves 8 3 2 6 DHW safety valve 8 4 MAINTENANCE 9 5 START UP 9 6 DELIVERY OF THE INSTALLATION 9 7 DRAINING THE TANK 10 8 SPARES LIST 11 8 1 HOT WATER TANK 11 8 2 PLUGS AND EMBELLISHER 13 9 DIAGRAMS AND MEASUREMENTS 14 10 TECHNICAL CHARACTERISTICS 16 ...

Page 4: ... very low temperatures precautions will need to be taken to prevent damage to the installation It is recommendable to add anti freeze to the water in the primary circuit of the tank The anti freeze used must be compatible with public health regulations and it must not be toxic DOMUSA TEKNIK recommends the use of propylene glycol consulting the product manufacturer before use If the installation is...

Page 5: ...P SP V ES C Sa R Tpr SS EP Primary inlet SP Primary outlet ES Domestic cold water inlet SS Domestic hot water outlet V Drain socket R Resistance socket C Recirculation socket Sa DHW tank temperature probe Tpr Cathode protection connector ...

Page 6: ...it 4 SANIT S 750 ES SS EP SP V SP C R 1 1 Bridge cover SP Primary outlet EP Primary inlet ES Domestic cold water inlet SS Domestic hot water outlet V Drain socket R Resistance socket C Recirculation socket ...

Page 7: ...NIT S 1000 1000 SBH ES SS EP V SP C R 1 1 Bridge cover SP Primary outlet EP Primary inlet ES Domestic cold water inlet SS Domestic hot water outlet V Drain socket R Resistance socket C Recirculation socket ...

Page 8: ...ter circuit After doing so proceed to fill the primary circuit Ensure the secondary circuit is full before filling the primary circuit Place dielectric sleeves on the secondary circuit connections If the cold water pressure is higher than the pressure the appliance is designed for a pressure reducer should be installed calibrated to no higher than the design pressure To prevent heat loss through t...

Page 9: ... of storage heaters To install it carefully read the assembly instructions supplied with the cathodic protection Figure 1 3 2 3 Electrical element All Sanit hot water tanks have a socket for connecting an electrical element DOMUSA TEKNIK optionally supplies three elements of 1 5 2 5 and 3 5 kW To install them carefully read the assembly instructions supplied with the elements Figure 2 3 2 4 18L DH...

Page 10: ...e of stainless steel To install the dielectric sleeves carefully read the assembly instructions supplied with them Figure 4 3 2 6 DHW safety valve All Sanit hot water tanks are designed to work at a maximum DHW pressure of 0 7 MPa 7 bar To prevent this pressure from being exceeded DOMUSA TEKNIK recommends fitting a safety valve to the DHW circuit calibrated to a maximum of 0 7 MPa 7 bar The safety...

Page 11: ...ommended for the user to periodically check the pressure and temperature levels of the hot water tank and the state of the valves connections and accessories 5 START UP For the guarantee to be valid the hot water tank must be started up by an Official DOMUSA TEKNIK Technical Assistance Service Before starting it up the following must be ensured The installation is filled with water and the drainin...

Page 12: ...then connect a hose to the drain socket on the bottom of the tank Check the hose is correctly connected to the tank drain socket Run the hose to a nearby floor drain This must be at a lower level than the tank The water begins to flow and wait until it drains completely SANIT S 500 750 1000 1000 SBH ...

Page 13: ... Hot water tank COMMONS SPARE PARTS 1 2 3 4 5 SANIT S 750 SANIT S 1000 1000 SBH Pos Name Code 1 Elliptical plug SCON000090 SCON000430 2 Bridge SPIN000006 3 M8 washer CTOR000080 4 M8 nut CTOR000092 5 Bridge cover SOPE000025 ...

Page 14: ...Sanit 12 SANIT S 1000 1 2 3 4 6 5 Pos Code Name 1 Screw M14 x 35 2 Lateral joint 3 Lateral inox cover 4 M14 Nut 5 SCON001743 Lateral cover support 6 SCON001748 Lateral cover ...

Page 15: ...ck embellisher 2 2 2 3 CFER000085 black embellisher 3 2 4 CFER000084 black embellisher 2 5 CFER000134 1 red tapered plug 2 2 2 6 CFER000082 red tapered plug 1 1 1 7 CFOV000158 seal 1 1 1 8 CFOL000037 F brass plug 1 1 1 9 CFOL000021 M 1 chromed plug 1 1 1 10 CFER000090 Nut cover 1 1 1 11 CFER000083 Seal 1 1 1 12 CFER000080 F 1 red plug 2 2 13 CFER000008 F 1 red plug 2 ...

Page 16: ...Sanit 14 9 DIAGRAMS AND MEASUREMENTS V SP EP ES C Sa R Spc C SS EP ES R SP V V SP EP ES C R SS ...

Page 17: ...H 1 H Cold water inlet ES mm 220 270 305 Ø 1 M 1 M 1 M Recirculation socket C mm 600 1220 595 Ø H H H Resistance socket R mm 1000 1125 1115 Ø 1 1 4 H 1 1 4 H 1 1 4 H Hot water outlet SS mm 215 1655 1425 Ø 1 M 1 M 1 M DHW tank temperature probe Sa mm H Ø 900 Cathode protection connector Tpr mm H Ø 1200 Base measurement Ø mm 760 860 1060 Height measurement mm 1760 1940 1730 ...

Page 18: ...ume L 500 745 1000 Max storage temperature ºC 70 70 70 Max working pressure of hot water tank MPa bar 0 7 7 0 7 7 0 7 7 Max primary temperature ºC 85 85 85 Max primary working pressure MPa bar 1 10 1 10 1 10 Empty weight Kg 120 166 240 Full weight Kg 620 916 1240 Exchange surface m2 1 8 2 4 3 2 ...