PRECAUTIONS
Sanit
hot water tanks must be installed by qualified staff in compliance with applicable
regulations.
Any work must be carried out by the official Technical Assistance Service, as any changes to its
configuration could cause functioning errors and could damage the system and its surrounding
environment.
This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack o experience and knowledge if they have been
given supervision or instruction concerning use if the appliance in a safe way and understand th
hazards involve. Children shall not play with the appliance. Cleaning and user maintenance shall
not be made by children without supervision.
The electrical main power supply connection must respect the current legislation, making
possible a complete disconnection of the tank, in order to make any maintenance operation
safely. Look "Diagram and electrical connection" chapter.
The hydraulic installation must be made by qualified technicians, in compliance with the current
installation regulations.
1.1
Frost precautions
When there is danger of frost, and particularly in areas with very low temperatures, precautions
will need to be taken to prevent damage to the installation. It is recommendable to add anti-
freeze to the water in the primary circuit of the tank. The anti-freeze used must be compatible
with public health regulations and it must not be toxic
. DOMUSA TEKNIK
recommends the use
of propylene glycol, consulting the product manufacturer before use.
If the installation is to be out of use for a long period,
drain all the water from the tank
.
1.2
Water characteristics
The water must comply with the characteristics defined in the Technical Building Code, and
must be treated if necessary.
The water must be in accordance with Directive 98/83 / EC on the quality of water intended for
human consumption. Special attention must be paid to the following parameters:
- Maximum chloride concentration: 250 mg / l.
- Maximum sulphate concentration: 250 mg / l.
- Maximum concentration of chlorides and sulphates: 300 mg / l.
- Maximum conductivity: 800 µS / l.
When the chlorine concentration in the Domestic Water exceeds 250 mg / l., it is recommended
that anti-corrosion protection should be applied to the inside of the inter-accumulator so as to
avoid its premature deterioration. As an option
DOMUSA TEKNIK
supplies electronic cathodic
protection that is suitable for the Sanit inter-accumulator range. To install it, read carefully the
assembly instructions that are provided with the same.