Evolution Solar HFD
20
10
TEMPERATURE SELECTION
10.1
Selecting the boiler setpoint temperature
The desired boiler operating temperature is selected using the touch button, as shown in the
figure. To select the desired temperature, touch the "
+
" or "
-
" symbols to increase or decrease the
temperature respectively. When the temperature has been selected, the display will return to
standby mode after a few seconds.
The boiler setpoint temperature can also be selected by using the MODE touch button to browse to
the “
boiler setpoint temperature
" display option. When the display shows this option, touch the "+
/-" symbols to select the desired temperature.
If you wish to totally disable the boiler heating function (
Summer
mode), select the setpoint value
"
OFF
" by touching the "-" symbol until this value appears on the display.
The permitted boiler setpoint temperature range is OFF and 30 - 85 ºC.
Evolution
model boilers are
condensing boilers. In order to obtain maximum boiler performance and energy savings, it is
therefore recommended to select a setpoint temperature of 55-70 ºC, providing this is permitted by
the heating system installed and the insulation conditions of your home.
10.2
Selecting the back-up DHW setpoint temperature
The desired DHW temperature is selected using the touch button, as shown in the figure. To select
the desired temperature, touch the "
+
" or "
-
" symbols to increase or decrease the temperature
respectively. When the temperature has been selected, the display will return to standby mode
after a few seconds. The DHW setpoint temperature range permitted is OFF and 30 - 65 ºC.
The DHW setpoint temperature can also be selected by using the MODE touch button to browse to
the “
DHW setpoint temperature
" display option. When this option appears on the display, touch
the "+ /-" symbols to select the desired temperature.
If you wish to totally disable the boiler’s DHW production function, select the setpoint value "
OFF
"
by touching the "-" symbol until this value appears on the display. In this case DHW will only be
produced by the boiler’s solar heating system.