Evolution EV HAM
32
22.6
Technical specifications
MODEL
EVOLUTION EV 25
HAM
EVOLUTION EV 35
HAM
Consumption max.
Kg/h
2,3 3,1
Power kW
27 37
Motor power.
W
200
Functioning type
On/Off
Power supply
220 V - 50 Hz
22.7
Nozzles
Evolution
boilers are supplied with the burner fitted, together with its corresponding nozzle and a
standard pre-adjustment. The following table shows the nozzles and adjustments for each particular
model:
MODEL Nozzle
Burner pressure
(bar)
Air
adjustment
Line
adjustment
EVOLUTION EV 25 HAM
0,60 80º H
10
4
1
EVOLUTION EV 35 HAM
0,75 60º H
12
4
1
22.8
Electrical connection diagram
1
2
5
6
8
10
11
12
3
FR
TR
∼
MB
EV1
LB
RP
Black
Blue
TC
TS
Ph
N
4
EV2
Pre-heater
F
7
Blue
Br
own/
Bl
ac
k
TC:
Boiler Thermostat.
TS:
Safety Thermostat.
F:
Fuse.
LB:
Cut-out Light.
FR:
Photocell.
TR:
Transformer.
MB:
Motor Pump.
EV:
Valve.
RP:
Preheater.
Ph:
Phase.
N:
Neutral.
Summary of Contents for EVOLUTION EV 25 HAM
Page 1: ...INSTALLATION AND OPERATING INSTRUCTIONS EVOLUTION EV HAM ...
Page 42: ...Evolution EV HAM 40 NOTAS ...
Page 43: ......