The Mayfair is a cartridge type centrifugal extractor fan. It is fitted with a maintenance free 
rubber mounted motor. The cartridge system permits the fan to be removed from the wall or 
ceiling without disturbing the ductile wiring or wall fittings. The facility greatly simplifies main-
tenance and cleaning procedures.

On new build and renovation projects the Mayfair 2000 fan permits all the installation work 
to be carried out in advance of the fan being fitted, thereby reducing the possibility of theft 
or damage. The Mayfair 2000 range is available with a wider range of features than any other 
extractor fan. It is a high quality product and will give many years of reliable service.

APPLICATION

BATHROOMS, TOILETS, UTILITY ROOMS, LOBBIES AND HALLWAYS

The Mayfair 2000 complies with all current Building Regulations.

Description

Model 70 

70m

3

/h (20 l/s) 

43m

3

/h

Extract

Volume

High Speed

Extract

Volume

Low Speed

Options

Single Speed
Single Speed/Pull-Cord
Single Speed/Time Delay
Twin Speed
Twin Speed/Time Delay
Single Speed/Condensation
Control/Time Delay

Twin Speed/Time Delay/Condensation Control for 
Remote Switching with Additional Pull-Cord Boost
Single Speed/

Infra Red Control

Model 70

MSS 070B

MPC 070B
MTD 070B

MTS 070B
MTT 070B

MCC 070B

MCT 070B

MIR 070B

Product Codes

Models

S/L

N

P/L

OPERATING SWITCH

ISOLATOR SWITCH

N

L

FRAME TERMINALS

S/L = SWITCH LIVE

N = NEUTRAL

P/L = PERMANENT LIVE

MTD 070B
MTS 070B 

MTT 070B

MCC 070B

MCT 070B

NOTE: THE OPERATING SWITCH MUST BE SINGLE POLE

Summary of Contents for MTD 070B

Page 1: ...by breathing through the sensor grille on the front cover Note There is a short delay between breathing through the grille and the fan starting Do not use steam from a kettle to test the unit CLEANING MAINTENANCE From time to time the fan unit will need cleaning To do this first isolate power supply Remove front cover as described above Remove the fan from its mounting by undoing the four corner s...

Page 2: ...and will give many years of reliable service APPLICATION BATHROOMS TOILETS UTILITY ROOMS LOBBIES AND HALLWAYS The Mayfair 2000 complies with all current Building Regulations Description Model 70 70m3 h 20 l s 43m3 h Extract Volume High Speed Extract Volume Low Speed Options Single Speed Single Speed Pull Cord Single Speed Time Delay Twin Speed Twin Speed Time Delay Single Speed Condensation Contro...

Page 3: ...ated and do not require earthing The mounting system is provided with an earth termination for convenience only Wiring Installation S L N S L N OPERATING SWITCH ISOLATOR SWITCH FRAME TERMINALS S L SWITCH LIVE N NEUTRAL L N L N ISOLATOR SWITCH FRAME TERMINALS L LIVE N NEUTRAL Models MSS 070B Models MPC 070B MIR 070B A guide to Ventilation WHERE TO SITE YOUR FAN Incorrect siting of an extractor fan ...

Page 4: ...l as possible cut a hole through the wall to take a 100mm duct for the fan discharge This should slope downwards towards the outside to allow for condensation drainage When this is done position the building in frame with the discharge outlet at the top right over the duct hole Mark around the frame and cut an aperture to take the frame and fan It is important that the front edge of the frame is f...

Reviews: