WARNING:
The Led MODULE, the power supply cable or any switch used,
are not replaceable, therefore in case of damage the device
must be entirely substituted.
WARRANTY:
The warranty on the device is valid only if powered by a
power supply provided by DOMUS Line. The warranty’s
general terms and conditions for this device are available at
www.domusline.com
HOW DOES THE ICY IFR WORK?
– The
ICY IFR
includes an electronic presence-detecting sensor
that can automatically switch on and off the lighting profile.
– The sensor (E) detects temperature changes combined with the
movement of people, animals and objects with a temperature of
36°C, within the range as indicated in figure 7. In this case the
sensor is activated and turns on the device, which remains in
operation for approximately 30 seconds. After that, if no other
changes are detected, it turns off automatically.
– Detection field must not be obstructed by shelves or object
positioned too close of the sensor (fig.6)
WARNING:
– This device must be connected directly to the power supply
and must never be connected downstream of other
electronic switches or be close to electromagnetic sources or
heat sources, and must not be exposed to direct light.
– The
ICE IFR
functions normally 40 seconds after it is first
switched on. During the 40-second start-up phase, the
sensor automatically sets up the device by detecting the
installation conditions. This is why it is necessary to wait until
the procedure is completed before using the device normally.
– The device must not be installed with the sensor close to
electromagnetic sources or heat sources, and must not be
exposed to direct light.
– Significant changes in temperature, or the movement of
objects within the sensor detection “cone” caused, for
example, by air conditioning units, fans, smoke and steam,
may stop the sensor device from functioning properly.