background image

 

 

 

 

 

Manuale GSMC2G - Ver. 11.17 

 

Pagina 1 

 

 

 

 

MANUALE D’ISTRUZIONI

 

GSMC2G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ricevitore GSM 1 relè – 2 

ingressi – batteria a tampone 

 

Summary of Contents for GSMC2G

Page 1: ...Manuale GSMC2G Ver 11 17 Pagina 1 MANUALE D ISTRUZIONI GSMC2G Ricevitore GSM 1 rel 2 ingressi batteria a tampone...

Page 2: ..._______________________________________________________________________________________________________________________ ________________________________________________________________________________...

Page 3: ...Schema elettrico di collegamento 8 Esempi di connessione 8 Configurazione tramite sms 12 Installazione e primi passi 12 Associazione GSM operazione obbligatoria 12 Cambio password 12 Aggiungere un nu...

Page 4: ...onale qualificato Leggere attentamente il manuale d uso prima di installare e controllare il GSMC2G Installare il GSMC2G in un luogo protetto e coperto Evitare che l acqua entri nel GSMC2G Non utilizz...

Page 5: ...gistrabili fino a 999 PRESENTAZIONE DEL PRODOTTO Il GSMC2G un controllore GSM a distanza E un apparecchio molto semplice e pu essere utilizzato per controllare l accesso a porte cancelli il controllo...

Page 6: ...ICHE Quad band pu funzionare con le reti telefoniche di tutto il mondo Nessun costo di chiamata il GSMC2G rifiuta la chiamata in entrata analizza se il numero un numero autorizzato ed automaticamente...

Page 7: ...to SIM card non leggibile oppure mancanza di rete CONNESSIONE TERMINALI Alimentazione Ingresso alimentazione cavo positivo rosso Ingresso alimentazione cavo negativo nero Input digitale Stato porta IN...

Page 8: ...GSMC2G e la serratura elettrica tramite la stessa fonte elettrica La serratura si attiva tramite chiamata telefonica GSMC2G per controllo remoto La pompa viene attivata disattivata tramite una chiama...

Page 9: ...r motivi di sicurezza il GSMC2G non risponde con SMS di avviso se il comando digitato errato Semplicemente il GSMC2G non considerer il comando Inizializzazione del GSM con la SIM card operazione obbli...

Page 10: ...to di un numero di telefono autorizzato a tempo determinato Inviare al numero telefonico della SIM card inserita nel GSMC2G pwdAposizione num_tel_utente t_inizio t_fine pwd password corrente A comando...

Page 11: ...ioni effettuate come pi avanti descritto monostabile bistabile ecc DD comando per spegnere il rel rel OFF Per il comando sopra descritto necessario essere in possesso della password L amministratore d...

Page 12: ...qualsiasi numero di telefono potr ora comandare aprire o chiudere il cancello il GSM anche se non inserito autorizzato Di default questa impostazione disabilitata Autorizzare solo i numeri inseriti n...

Page 13: ...er con un messaggio Relay ON will return SMS Porta Aperta Da quel momento in poi l utente in posizione 001 e il numero chiamante riceveranno una notifica SMS con scritto Porta Aperta ogni volta che il...

Page 14: ...M card inserita nel GSMC2G pwdT pwd password corrente T comando per richiedere stato impostazione controllo Per esempio 1234T Il GSMC2G invier un messaggio di risposta Report status every 008hours Con...

Page 15: ...pio 1234DIN2NO questo comando definisce l ingresso DIN2 come NO normalmente aperto Modificare l SMS di allerta quando viene inviato l impulso dell input massimo 32 caratteri pwdM1 2 smsContenuto per e...

Page 16: ...Manuale GSMC2G Ver 11 17 Pagina 16 LISTA NUMERI AUTORIZZATI Posizione Numeri telefono autorizzati Nome utilizzatori Autorizz illimitata Tempo autorizzazione 1 Numero di servizio X 2 3 4 5 200...

Page 17: ..._______________________________________________________________________________________________________________________ ________________________________________________________________________________...

Page 18: ...a 18 Domotime srl Sede legale Via Michelangelo 152 B 25015 Desenzano d G BS Italy Sede operativa Via Monico 9 25017 Lonato d G BS Italy Tel 39 030 9913901 Fax 39 030 9901307 Skype domotime email info...

Page 19: ...Manuale GSMC2G Ver 11 17 Pagina 19 INSTRUCTIONS MANUAL GSMC2G GSM receiver 1 relay 2 input backup battery...

Page 20: ...________________________________________________________________________________________________________________________ _______________________________________________________________________________...

Page 21: ...ay open close by telephone call 9 Activating relay open close by SMS text message 9 Setting and managing 10 Enquiring authorized numbers position 10 Deleting a stored phone number 10 Authorizing any c...

Page 22: ...ser manual carefully before installing and managing the GSMC2G recevier Install the GSMC2G receiver in a protected and covered place Avoid the water entering the GSMC2G receiver Do not use the GSMC2G...

Page 23: ...o doors gates as well as remote electrical or electronic devices The device can be used in any circumstance where you need to turn on or off any equipment by a free phone call or by SMS from a mobile...

Page 24: ...atically activates or deactivates the relay Suitable for multiple applications gates bollards barriers garage doors shutters and access doors etc Secure the device is a caller identification system An...

Page 25: ...o seconds normal state Off SIM card not readable or power failure TERMINAL CONNECTIONS Power supply Power input positive red Power input negative black Digital input Port status DIN1 to be connected a...

Page 26: ...ng Power the GSMC2G and the electric lock using the same electrical source The lock is activated by telephone call GSMC2G for remote control The pump is activated deactivated via phone call The pump i...

Page 27: ...prefix to the GSM SIM card number e g 39 for Italy For security reasons GSMC2G will not respond with SMS if the typed command is incorrect Simply the GSMC2G will not consider the command Initializing...

Page 28: ...d to GSMC2G SIM card number pwdAposition num_tel_user t_start t_end pwd current password A command for storing a new authorized phone number position storage location of the new number in the GSM from...

Page 29: ...ble etc DD command for switching off the relay relay OFF For above command it is necessary to know the password The administrator of GSM receiver will be anyone who knows the password SETTINGS AND MAN...

Page 30: ...is disabled Authorizing only stored phone numbers Send to GSMC2G SIM card number pwdAUT pwd current password AUT command for authorizing only the stored phone numbers GSMC2G will send a SMS text mess...

Page 31: ...perta From that moment on the user in position 001 and the calling number will receive a SMS message with Porta Aperta whenever the relay is activated ON 1st position in GSM stored list should be rese...

Page 32: ...y is not active 000 Enquiring self check status Send to GSMC2G SIM card number pwdT pwd current password T command for enquiring self check status Example 1234T GSMC2G will send a reply SMS text Repor...

Page 33: ...N2NC NO per esempio 1234DIN2NO questo comando definisce l ingresso DIN2 come NO normalmente aperto Modificare l SMS di allerta quando viene inviato l impulso dell input massimo 32 caratteri pwdM1 2 sm...

Page 34: ...Manuale GSMC2G Ver 11 17 Pagina 34 AUTHORIZED NUMBERS LIST Position Authorized phone numbers Users names Unlimited authoriz Authorization window 1 Numero di servizio X 2 3 4 5 200...

Page 35: ...________________________________________________________________________________________________________________________ _______________________________________________________________________________...

Page 36: ...a 36 Domotime srl Sede legale Via Michelangelo 152 B 25015 Desenzano d G BS Italy Sede operativa Via Monico 9 25017 Lonato d G BS Italy Tel 39 030 9913901 Fax 39 030 9901307 Skype domotime email info...

Reviews: