VPR 3P

FEATURES :

INPUT SPECIFICATION :

DISPLAY AND KEY :

GENERAL SPECIFICATION :

Protection Available

3 digit bright LED display
Manual/Auto Reset option, Self powered

Time parameter: Power on delay, Recovery Time(Auto reset) 

Trip delay 

Over Voltage

Asymmetry

Over Frequency

Phase Sequence

Under Voltage

Phase Loss

Under Frequency

Direct Voltage AC 

Frequency 

Resolution  

  Accuracy 

VOLTAGE PROTECTION RELAY

280 to 520V AC ( L - L ) 3Ø-3W 
160 to 300V AC ( L - N ) 3Ø-4W 

45.0 Hz to 65.0 Hz  

Class 1.0 

Display

Dimension (mm) 

Keys

Trip Setting

3 digit, 1line, 7 seg, 0.4” RED LED

75 (H) x 45 (W) x 110 (D) mm

SET, INC, DEC/RST

OUTPUT SPECIFICATION :

Relay

Relay Type

Rating

2 nos.

1  C/O (NO-C-NC)

st

1  Relay 10A, 230V AC

nd

2  Relay 5A, 230V AC

AUXILIARY SUPPLY :

Self powered, 30 VA  MAX

Under voltage : 

 Over voltage   :   

Over Frequency : 45.0 Hz To 65.0 Hz

ENVIRONMENT CONDITION :

Relative Humidity

 Operating Temp.

0°C to 55°C

UP to 95% RH 
(non-condensing)

TECHNICAL SPECIFICATION

MECHANICAL INSTALLATION

Front View(mm)

1 Volt

Under Frequency : 45.0 Hz To 65.0 Hz

Phase Asymmetry : 2-30%

Time Parameter

Power ON Delay Time : 0 To 99 Sec.

Trip delay Time : 0 To 999 Sec.

Recovery Time : 0 To 99 Sec.

TERMINAL CONNECTION

110

75

75

Side View(mm)

L1

NC

R2

R1

NC

C

C

NO

NO

L2 L3 N

VPR 3P

V

L1

R2

R1

L2 L3

SET

L1

L2

L3

N

TO

LOAD

L1

NC

R2

R1

NC

C

C

NO

NO

L2 L3 N

SET

VPR 3P

L1

R2

R1

L2 L3

V

(260-520V AC,3Ø-3W)

(260-520V AC,3Ø-3W)

(160-300V AC,3Ø-4W)

(160-300V AC,3Ø-4W)

Class 1.0 (Standard)

ACCURACY

Summary of Contents for VPR 3P

Page 1: ...IFICATION Relay Relay Type Rating 2 nos 1 C O NO C NC st 1 Relay 10A 230V AC nd 2 Relay 5A 230V AC AUXILIARY SUPPLY Self powered 30 VA MAX Under voltage Over voltage Over Frequency 45 0 Hz To 65 0 Hz ENVIRONMENT CONDITION Relative Humidity Operating Temp 0 C to 55 C UP to 95 RH non condensing TECHNICAL SPECIFICATION MECHANICAL INSTALLATION Front View mm 1 Volt Under Frequency 45 0 Hz To 65 0 Hz Ph...

Page 2: ...t breaker must be installed at convenient place normally accessible to the operator INSTALLATION GUIDELINES 3 Use and store the instrument within the specified ambient temperature and humidity ranges as mentioned in this manual 1 The equipment should be cleaned regularly to avoid blockage of ventilating parts 2 Clean the equipment with a clean soft cloth Do not use isopropyl alcohol or any other c...

Page 3: ...er Frequency is Disable A S 1 Asymmetry Of Relay 1 If Asymmetry is Enable 2 0 Asymmetry Percentage 2 30 If Asymmetry is Disable Press key for save exit SET Press key SET Press key SET Press key SET Press key SET Press key SET Press key SET Press key SET Press key SET Press key SET Press key SET Press key SET Press key SET Press key SET Press key SET Press key SET Press key SET Press key SET u V 1 ...

Page 4: ...inuous process So for more updated operating information and Support Please contact our Helpline 9978991476 9978991474 9978991482 or Email at Ver 191201 service multispanindia com FAULT MESSAGE 4 0 0 Scroll u v 3 2 0 Scroll O F 5 2 0 Scroll Over Frequency Fault Over Frequency Value 52 0 Hz U F A S P L P S L1 L2 L3 R1R2 L1 L2 L3 R1 R2 L1 L2 L3 R1 R2 L1 L2 L3 R1 R2 L1 L2 L3 R1 R2 L1 L2 L3 R1 R2 Note...

Reviews: