(18)
EPT052026 Issue 1 February 2019
Set Box/Lot
Counter
^1k01CS
*x*y*z*
a*b*c*d
\0
*x
: Counter number.
Range = 00-03. This is
the name of the counter
that will be stored on the
printer. Each box/lot uses
2 counters.
*y
=0: Count upwards.
*y
=1: Count downwards.
*z
=0: Do not fill zeros.
*z
=1: Fill zeros.
*a
: Counter steps. Range
= 000-250 (mandatory 3
characters).
*b
: Counter start value.
Range = 0000000001-
2000000000 (mandatory
10 characters).
*c
: Current counter value.
Range = 0000000001-
2000000000 (mandatory
10 characters).
*d
: Counter reset value.
Range = 0000000001-
2000000000 (mandatory
10 characters).
*e
: Current repeat value.
Range = 0000000000-
0010000000 (mandatory
10 characters).
Note:
A pair of counters
is required for a
box/lot. The
command will need
to be sent twice.
1k01CS00010010000000001
00000000010000000999\0 =
Set counter 0 of box/lot1.
1k01CS01010010000000001
00000000010000000999\0 =
Set counter 1 of box/lot1
Set date format
^1A
*x
1CS
*y
\0
*x
: The number of the
date format. Range = 0-4.
The printer supports up to
5 date formats.
*y
: Date format string.
Maximum length = 13
characters
Valid characters =
(D,d,M,m,Y,y,J,j, - , /, . , _
, |, SPACE)]
^1A01CSDDMMMYYYY\0 =
The printer will print the date as
11Sep2019
8080
Set time format
^1I01CS
*x
\0
*x
: The time format string.
Maximum length = 12
characters
Valid characters = (H, h,
m, s, t, :, - , . , _ , |,
SPACE)]
^1I01CShh:mm tt\0 = The
printer will print the time as
10:30 PM
^1I01CSHH:mm\0 = The printer
will print the time as 22:30
8080
Table 1: PC to Printer
Operation
Command
Parameter
Examples
UDP Port