EN
Operation
CoolMatic FC40
28
6.7
Replacing the plug fuse (12/24 V)
➤
Pull the adapter sleeve (fig.
3
4, page 3) off of the plug.
➤
Unscrew the screw (fig.
3
5, page 3) out of the upper half of the housing
(fig.
3
1, page 3).
➤
Carefully raise the upper half of the housing from the lower (fig.
3
6,
page 3) half.
➤
Take out the contact pin (fig.
3
3, page 3).
➤
Replace the defective fuse (fig.
3
2, page 3) with a new one that has the
same rating (8A 32V).
➤
Re-assemble the plug in the reverse order.
6.8
Defrosting the cooler
Humidity can form frost in the interior of the cooling device or on the evapo-
rator. This reduces the cooling capacity. Defrost the device in good time to
avoid this.
A
NOTICE! Danger of damage!
Never use hard or pointed tools to remove ice or to loosen objects
which have frozen in place.
To defrost the cooler, proceed as follows:
➤
Take out the contents of the cooling device.
➤
If necessary, place them in another cooling device to keep them cool.
➤
Switch off the device.
➤
Leave the lid open.
➤
Wipe off the defrosted water.