EN
CF18 – CF60
Technical data
27
I
The refrigerant circuit contains R134a.
Contains fluorinated greenhouse gases
Hermetically sealed equipment
CF50
CF60
Connection voltage:
12/24 V
g
and 100 – 240 V
w
Rated current
– 12 V
g
:
7.0 A
– 24 V
g
:
3.0 A
– 100 – 240 V
w
:
1.3 A to 0.7 A
Cooling capacity:
+10 °C to –18 °C (+50 °F to 0 °F)
Gross volume:
48 l
58 l
Storage volume:
46 l
55 l
Climate class:
N or T
Ambient temperature:
18 °C to 43 °C (+64.4 °F to 109.4 °F)
Noise emission:
45 dB(A)
Refrigerant quantity:
45 g
55 g
CO
2
equivalent:
0.064 t
0.079 t
Global warming potential (GWP):
1430
1430
Dimensions (W x H x D) in mm
(with handles removed):
630 x 480 x 360
630 x 580 x 360
Dimensions (W x H x D) in mm
(including handles):
760 x 480 x 360
760 x 580 x 360
Weight:
18.5 kg
20.6 kg
Test/certificates:
NOTE
If the ambient temperature is above 32 °C (90 °F), the minimum
temperature cannot be attained.
CF18-CF60-O-AUS.book Seite 27 Dienstag, 17. September 2019 8:49 08