Skyscreen Powered
Troubleshooting
Replacing the fabric panel
➤
Fabrics can be removed for cleaning or replacement (fig.
9
, page 7 and
fig.
0
, page 7 for installations without headlining or fig.
a
, page 8 for
installations with headlining).
Due to batch variation, replacement fabric colours may vary slightly in shade.
10
Troubleshooting
Fault
Solution
Moving rail not straight
➤
Disconnect the first fabric panel at the
opposite end to the crooked moving
rail (fig.
9
, page 7 and fig.
0
, page 7
for installations without headlining or
fig.
a
, page 8 for installations with
headlining).
➤
Adjust the coupling (fig.
b
, page 8).
Moving rail jams.
➤
Check the side tracks for debris or
obstructions.
Motor not working
➤
Check if wiring for voltage to the motor
is correct.
➤
If power supply is checked and the
motor is still faulty contact your
distributor.
➤
If using the AP Remote control refer to
the AP Remote control manual.
Motor running slow or fast
➤
Check for correct supply voltage.
AP Remote control (optional) not operat-
ing
➤
Refer to the AP Remote control
manual.
Motor runs but blind does not move
➤
Check inside the side tracks for
obstructions.
➤
Check that the side tracks have been
installed properly and have not been
twisted or distorted too far in or out.