9
3-4-5. Set the power switch to the ON position. Check the meters and
indicators on the front panel of the inverter. The voltage bar
graph should indicate 11 to 14 volts (22 - 28V when 24V
version is used) depending on the voltage level of the power
source. If there is no indication, check your power source and
the connections to inverter.
The other indicators should be off.
3-4-6. Set inverter switch to the OFF position, the indicator lights may
blink and the internal alarm may sound momentarily.
This is normal. Plug the test load (maximum 1500W resistive
load) into the AC receptacle on the front panel of the inverter.
Leave the test load switched off.
3-4-7. Set inverter switch to the ON position and turn the test load On.
The inverter should supply power to the load. If you plan to
accurately measure the true output r.m.s. voltage of inverter, a
meter such as FLUKE 45, BECKMAN 4410 or TRIPLETT 4200
must be used. (True RMS multimeter must be used).
Summary of Contents for SI 1500
Page 2: ...Dometic SI 1500 Pure Sine Wave Inverter 230Vac from 12Vdc 24Vdc source User s Manual ...
Page 8: ...4 2 3 Mechanical Drawings PURE SINE WAVE 230V AC 50Hz 1500W ...
Page 28: ...24 Further Information about Dometic products www dometic com ...
Page 36: ...5 2 3 Mechanische Zeichnungen PURE SINE WAVE 230V AC 50Hz 1500W ...
Page 59: ...28 Weitere Informationen über Dometic Produkte www dometic com ...
Page 67: ...5 2 3 Dessins mécaniques PURE SINE WAVE 230V AC 50Hz 1500W ...
Page 90: ...28 Informations complémentaires sur les produits Dometic www dometic com ...
Page 98: ...5 2 3 Mekaniska ritningar PURE SINE WAVE 230V AC 50Hz 1500W ...
Page 120: ...27 Ytterligare information om produkter från Dometic www dometic com ...
Page 128: ...5 2 3 Disegni meccanici PURE SINE WAVE 230V AC 50Hz 1500W ...
Page 148: ...25 Informazioni supplementari sui prodotti Dometic www dometic com ...
Page 157: ...6 2 3 Ilustraciones mecánicas PURE SINE WAVE 230V AC 50Hz 1500W ...
Page 179: ...28 Más información sobre los productos Dometic www dometic com ...
Page 180: ...Cod ST 069 DOMETIC WTA Via Virgilio 3 47100 Forlì Tel 0543 754213 Fax 0543 756631 ...