Installing the refrigerator
RUC8408X
12
•
The outer wall must be fitted with one air inlet ventilation grille (fig.
4
2a,
page 12) and one outlet ventilation grille (fig.
4
2b, page 12) so that the heat
generated can be easily released to the outside:
– Lower air inlet vent LS300 can be installed from flush to the vehicle floor up to
a maximum height (top of vent) of 300 mm below the compressor shelf.
– Upper air outlet vent LS300 must be installed with the bottom of the vent no
lower than the compressor shelf. Higher than the compressor shelf is
allowed, but for optimum service access as close as possible to the compres-
sor shelf height is recommended.
Pos. in
fig.
4
,
page 12
Description
1
Maximum height to 300 mm below the compressor shelf
2
LS300 vent
3
Minimum height is equal to the height of the compressor shelf
4
Air deflection plate