Connecting the refrigerator
RUA5208X, RUA6408X, RUA8408X
EN
24
7
Connecting the refrigerator
7.1
Connecting to the gas supply
A
I
It must be possible to shut off the refrigerator from the gas line separately by means of a shut-off
device. The shut-off device must be easily accessible.
1. Connect the refrigerator securely to the gas supply (fig.
, page 24). Always use a back up
wrench when loosening and tightening connections.
2. Have a leak test and a flame test performed by an authorised specialist after professional instal-
lation. Ensure you are issued with a certificate of inspection.
NOTICE!
• This refrigerator may only be connected to the gas supply by a specialist in accord-
ance with the applicable guidelines and standards.
• Only use cylinders of universal LPG gas fitted with an approved gas pressure regu-
lator. Compare the pressure information on the data plate with the pressure infor-
mation on the pressure regulator on the gas cylinder.
•
Only
operate the refrigerator at the pressure shown on the data plate.
•
Only
operate the refrigerator with the type of gas shown on the data plate.
• Please note the pressures which are permitted in your country. Only use pressure
controllers with a fixed setting which comply with the national regulations.
NOTE
The pressure of the gas supply must be 2.75 kPa. Check the pressure at the test point
before using the refrigerator (fig.
1
o