EN
Troubleshooting
RPD190, RPD 218
32
Compressor is not running (connected to AC supply)
Interior temperature too low on warmest control setting
U
Term
Voltage between the positive and negative terminals of the electronics
U
ON
Cut-in voltage of the electronics
U
OFF
Cut-off voltage of the electronics
Fault
Possible cause
Remedy
Device does not
function, Power LED
does not glow
Connection supply line interrupted
Establish a connection.
Main switch faulty (if installed)
Replace the main switch.
Additional supply line fuse has blown
(if installed).
Replace the supply line
fuse.
The integrated mains adapter is
defective.
This can only be repaired
by an authorised repair
centre
The device does not
cool (power is present,
power LED is lit)
Defective component
This can only be repaired
by an authorised repair
centre.
Voltage is being
applied, but the
compressor does not
operate
Ambient temperature too high
–
Insufficient ventilation
Clean existing ventilation
or install sufficient
ventilation.
Condenser is dirty.
Clean the condenser.
Fan defective (if installed)
Replace the fan.
Electric circuit between
the pins in the
compressor interrupted
Defective compressor
This can only be repaired
by an authorised repair
centre.
Fault
Possible cause
Remedy
Compressor runs
constantly
Control sensor faulty
This can only be repaired
by an authorised repair
centre.
Compressor runs for a
long time
Large quantities have been frozen in
the freezer compartment.
Wait until goods are
completely frozen.
RPD190-218--IO-AU.book Seite 32 Montag, 24. Oktober 2016 5:08 17