Dometic RM2662 Installation And Operating Instructions Manual Download Page 13

13

B. Check all connections in the LP gas system (at the

back of the refrigerator) for gas leaks. The LP gas
supply must be turned on. Apply a non-corrosive
bubble solution to all LP gas connections.

The appearance of bubbles indicates a leak and
should be repaired immediately by a QUALIFIED
SERVICEMAN WHO IS FAMILIAR WITH GAS SYS-
TEM AND REFRIGERATORS.

DO NOT use a wire or pin when cleaning the burner
jet as damage can occur to the precision opening.
This can cause damage to the refrigerator or create
a fire hazard.

! WARNING

9. Reinstall burner, being careful that the end of the

burner fits into the slot on the burner bracket. Check
to make sure slots are centered under the flue tube.

10. Check the electrode for proper location and gap.

(See FIG. 14).

11. Turn on manual gas shutoff valve and check all fit-

tings for leaks with soapy water.

12. Connect 120 volt power cord to the outlet and re-

connect or turn on the 12 volt DC power.

13. Check LP gas safety shutoff. See page 6.

TROUBLESHOOTING

The Refrigerator Does Not Cool Properly

A. Burner jet clogged.

Clean. (See Section Maintenance & Service, item 2.
Periodic maintenance, Paragraph E item 1-13.

B. Check level of refrigerator.

C. Venting problem.

Restriction in air flow across cooling unit.

D. Heavy frost buildup on evaporator fins.

Defrost.

E. Flue baffle not inserted properly in flue tube.

F. Improperly set thermostat.

See section Operating Instructions, part Start Up
Instructions.

G. Burner dirty.

Clean. (See section Maintenance & Service, item 2.
Periodic Maintenance, Paragraph E item 1-13).

! WARNING

DO NOT use a flame to check for gas leaks.

C. Check the AMES control system by connecting/dis-

connecting 120 volt AC power, start/stop the engine,
etc. Compare the operation with the operation de-
scribed in section Operating Instructions.

D. The LP gas pressure should be checked and read-

justed if necessary . The correct operating pressure
is 11 inches of water column. The correct place to
take the LP gas pressure is at the test port just ahead
of the burner jet. (See FIG. 12).

E. Inspect the flue baffle. It should be reasonably clean

and free of soot. Heavy soot formation indicates im-
proper functioning of the burner. The flue and burner
both require cleaning in the following manner:

1. Unplug the refrigerator power cord from the 120 volt

AC outlet. (See FIG. 3).

2. Disconnect or shut off the 12 volt DC power to the

refrigerator.

3. Turn manual shutoff valve to OFF. (See FIG. 1 & 12).

4. Remove cover from the burner housing. (See FIG. 1).

5. Remove the burner mounting screw and remove the

burner assembly. (See FIG. 12).

6. Remove the wire and flue baffle from the top of flue

tube. Clean the flue from the top using a flue brush.
Blowing compressed air into the flue will not properly
clean soot and scale out of the flue tube. Replace the
flue baffle.

7. Clean burner tube with a brush. Blow out burner with

compressed air.

8. Before removing burner jet, clean burner area of soot

and scale that fell out of flue tube. Remove the burner
jet. Soak the jet in wood alcohol and blow it out with
compressed air. Reinstall and tighten burner jet.

NOTE: The color of the flame shall be clear blue over
the slots of the burner. (See FIG. 13).

FIG. 14

Electrode

Burner tube

1/8” to 3/16”
(3-5 mm)

FIG. 13

Clear blue color
of flame

Summary of Contents for RM2662

Page 1: ...his or any other appliance WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information...

Page 2: ......

Page 3: ...icator Lamp GAS Mode Only F Temperature Indicator Lamps G Climate Control Switch LEGEND 2 WAY Model 1 Main Power Button ON OFF 2 AUTO GAS Mode Selector Button 3 Temperature Selector Button B AC Mode I...

Page 4: ...t be provided for ventilation of heavier than air fuel gases The lower vent of the recommended kits is provided with proper size openings The flow of combustion and ventilating air must not be obstruc...

Page 5: ...The top frame of the refrigera tor will be anchored to the wood strip with screws See FIG 10 The refrigerator must be installed in a substantial enclo sure and must be level When installing the refri...

Page 6: ...rigerator is connected to the LP gas supply To test the gas safety shutoff proceed as follows 1 Start the refrigerator and switch to GAS mode See start up instructions 2 Check that the gas flame is li...

Page 7: ...to the roof material For ven tilation height see table VENTILATION HEIGHTS See Figures 9 and 10 METHODS OF INSTALLATION The method of installation is shown in FIG 9 It is essential that all maximum or...

Page 8: ...l as the rolling and pitching movement of the vehicle will pass to either side of level keeping the liquid ammonia from accumulating in the evaporator tubing OPERATION Before starting the refrigerator...

Page 9: ...including the interior light START UP INSTRUCTIONS A A continuous 12 volt DC supply must be available for the electronic control to function B Press the main power ON OFF button 1 to the DOWN position...

Page 10: ...open If the problem is still not corrected con tact a service center for assistance If the control is switched to AC or DC 3 way models only operation while the CHECK indicator lamp is on it will func...

Page 11: ...ood compart ment To prevent food from drying out keep it in covered dishes containers plastic bags or wrapped in aluminum foil Ice cubes can be made in the freezer compartment For faster ice making th...

Page 12: ...Before working on the refrigerator make sure the AC voltage and DC voltage leads are disconnected Shut off the gas supply at the LP tank Disconnect the gas supply line at the rear of the refrigerator...

Page 13: ...agraph E item 1 13 WARNING DO NOT use a flame to check for gas leaks C Check the AMES control system by connecting dis connecting 120 volt AC power start stop the engine etc Compare the operation with...

Page 14: ...roper adjust ments and unfavorable installation conditions Contact service point or distributor service dept for assistance CHANGING DOOR HINGES FROM ONE SIDE TO THE OTHER The refrigerator is equipped...

Page 15: ...15...

Page 16: ...ter 325W 120V 17 37 57 09 7 B Heater 215W 12V 200 74 19 21 7 A B C Jet No 58 293 06 97 07 9 A B C Burner with conductor 293 20 93 03 8 A B C Handle black 293 21 06 01 2 A B C Lamp cover 293 25 75 05 9...

Page 17: ...side at the desired position Slide the wire shelf to the left The right hand side of the shelf will come loose Slide the shelf into the holes on the right hand side Lower the right hand side of the wi...

Page 18: ...18 RM2662 RM2862 RM2663...

Page 19: ...19...

Page 20: ...20 MO FO 0448...

Reviews: