C. Check the AMES control system by connecting/dis-

connecting 120 volt AC power, start/stop the engine,
etc. Compare the operation with the operation de-
scribed in section Operating Instructions.

D. The LP gas pressure should be checked and the main

regulator readjusted if pressure is incorrect. The cor-
rect operating pressure is 11 inches of water column.
The correct place to take the LP gas pressure is at
the test port just ahead of the burner jet. (See FIG. 9).

E. Inspect the flue baffle. It should be reasonably clean

and free of soot. Heavy soot formation indicates im-
proper functioning of the burner. The flue and burner
both require cleaning in the following manner:

1. Unplug the refrigerator power cord from the 120-volt

AC outlet. (See FIG. 8).

2. Disconnect or shut off the 12 volt DC power to the

refrigerator.

3. Turn manual shutoff valve to OFF. (See FIG. 1 & 9).

4. Remove cover from the burner housing. (See fig. 1).

5. Disconnect the wire from the high voltage electrode.

6. Remove the burner mounting screw and remove the

burner assembly. (See FIG. 9).

7. Remove the wire and flue baffle from the top of flue

tube. Clean the flue from the top using a flue brush.
Blowing compressed air into the flue will not prop-
erly clean soot and scale out of the flue tube.

Replace the flue baffle.

8. Clean burner tube with a brush. Blow out burner with

compressed air.

9. Before removing burner jet, clean burner area of soot

and scale that fell out of flue tube. Remove the burner
jet. Soak the jet in wood alcohol and blow it out with
compressed air. Reinstall and tighten burner jet.

DO NOT use a wire or pin when cleaning the burner
jet as damage can occur to the precision opening.
This can cause damage to the refrigerator or create
a fire hazard.

FIG. 11

Electrode

Burner tube

1/8” to 3/16”
(3-5 mm)

Clear blue color
of flame

FIG. 10

! WARNING

10. Reinstall burner, being careful that the end of the

burner fits into the slot on the burner bracket. Check
to make sure slots are centered under the flue tube
and the thermocouple is positioned properly (tip of
thermocouple extends over two slots of burner).

NOTE: The color of the flame shall be clear blue over
the slots of the burner. (See FIG. 10).

11. Be sure to reconnect the wire to high voltage elec-

trode. Check the electrode for proper location and
gap. (See FIG. 11).

12. Turn on manual gas shutoff valve and check all fit-

tings for leaks with soapy water.

13. Connect 120-volt power cord to the outlet and re-

connect or turn on the 12-volt DC power.

14. Check LP gas safety shutoff. See page 7.

F. FUSES

The refrigerator is equipped with 3 fuses, two fuses in
the power module and one in-line blade fuse.

Power module
To replace fuse(s) proceed as follows.
1. Disconnect the wall plug, and the 12 volt wires.

2. Remove the power module cover. See FIG. 1.

3. Snap the fuse out of the fuse holder.

4. Fit a new fuse in to the fuse holder.

5. Replace the power module cover.

Control system

3 Amp

AC heater

5 Amp

In line fuse
30 amp. blade fuse for the 12 volt DC heater

4. TROUBLESHOOTING

Refrigerator Does Not Cool Properly

A. Burner jet clogged.

Clean. (See section Maintenance & Service, Item 3.
Periodic Maintenance, Paragraph E. Item 1-14).

B. Check level of refrigerator.

C. Venting problem.

Restriction in air flow across cooling unit.

D. Heavy frost buildup on evaporator fins.

Defrost

E. Flue baffle not inserted properly in flue tube.

Summary of Contents for RM2354

Page 1: ...ppliance WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier Pour votre sécurité Si vous sentez une odeur de gaz 1 Ouvrez les fenêtres 2 Ne touchez à aucun interrupteur 3 Éteignez toute flamme nue 4 Avertissez immé...

Page 2: ......

Page 3: ...tor control panel FIG 2 ON OFF AC DC GAS AUTO CHECK COLD 1 2 3 4 5 COLDEST Travel latch 1 2 3 4 F C B A C E LEGEND 3 WAY AMES Model 1 Main Power Button ON OFF 2 DC Mode Selector Button 3 AUTO GAS Mode Selector Button 4 Temperature Selector Button A DC Mode Indicator Lamp B AC Mode Indicator Lamp C GAS Mode Indicator Lamp D AUTO Mode Indicator Lamp E CHECK Indicator Lamp Gas Operation Only F Temper...

Page 4: ... the mobile home or recreational vehicle Openings for air supply or for venting of combustion products shall have a minimum dimension of not less than 1 4 inch Proper installation requires one lower fresh air intake and one upper exhaust vent The ventilation kits shown in this instruction manual have been certified for use with the refrigerator models listed in the Table For Certified Vent System ...

Page 5: ... the bottom of the lower side vent to the roof material For ventilation height see table VENTILATION HEIGHTS See Figures 3a 3b and 4 This method of installation and these clearances will give you adequate space for service and proper installation Refrigerator Minimum ventilation heights in inches and mm model installation with Installation with roof RM2354 upper and lower vent and lower side side ...

Page 6: ...ront frame the refrigerator is to be se cured in the enclosure with five screws not included The screws have to be installed in the following order STEP 1 Four screws installed through the front frame See fig 7 STEP 2 One screw installed in rear base See fig 7 In the parts bag there are plugs to be snapped in the front frame to cover the four screw heads Drain water hose A hole must be drilled thr...

Page 7: ...ong from this plug The free length of the cord is 2 feet and therefore recommended that the receptacle be located to the left side of the refrigerator viewed from the rear and approximately 4 6 inches from the floor see FIG 8 This allows easy accessibility through the vent door The cord should be routed to avoid contacting the burner cover flue cover or any other components that could damage the c...

Page 8: ... see FIG 1 This refrigerator is equipped with a semi Automatic Energy Selector AMES control system which can be set to automatically select either 120 volt AC or LP gas operation AUTO mode or if desired LP gas only GAS mode On 3 way model the control system can manu ally be set to DC operation DC mode The refrigerator controls will work down to 9 6 volt DC PANEL DIMENSIONS MAX THICKNESS 5 32 4 mm ...

Page 9: ...0 volts AC is not available the GAS mode indicator lamp C will illuminate and the control system will automatically switch to GAS operation 3 If the CHECK indicator lamp E illuminates and the GAS mode indicator lamp C is off the controls have failed to ignite the burner in the GAS mode GAS operation may be reset by pressing the main power ON OFF button 1 to the OFF then ON posi tion See step 2 und...

Page 10: ...ator lamp will not go off until the main power ON OFF button is pressed to the OFF then ON position DC MODE When operating in the DC mode the DC mode indicator lamp A will be illuminated All other mode lamps will be off The DC mode overrides all other operating modes If one of the other operating modes is desired the DC selector button 2 must be pressed to turn OFF the DC lamp A IMPORTANT To preve...

Page 11: ...e lower compartment may be frozen if the set ting is left on COLDEST position Total Refrigerated Volume 3 cu ft DEFROSTING Shut off the refrigerator by pressing the main power ON OFF button to the UP OFF position Empty the refrig erator leaving the drip tray under the finned evaporator and the cabinet and freezer doors open Defrosting time can be reduced by filling the ice trays with hot water and...

Page 12: ... line loosen the screws anchoring the refrigerator to the enclosure and slide the refrigera tor out of the compartment When replacing the refrigerator make sure that the seal ing strips are properly positioned Replacement is the reverse of removal Check all con nections for gas leaks Refer to section INSTALLATION page 4 to 8 3 PERIODIC MAINTENANCE To keep your Dometic refrigerator operating effici...

Page 13: ...DO NOT use a wire or pin when cleaning the burner jet as damage can occur to the precision opening This can cause damage to the refrigerator or create a fire hazard FIG 11 Electrode Burner tube 1 8 to 3 16 3 5 mm Clear blue color of flame FIG 10 WARNING 10 Reinstall burner being careful that the end of the burner fits into the slot on the burner bracket Check to make sure slots are centered under ...

Page 14: ...e dept for assistance SPARE PARTS The following list is a list of commonly used parts which should be available if required from your Dometic Ser vice Center Part No Description 17 37 35 06 9 Heater 150W 12V 17 37 71 02 3 Heater 175W 120V 200 22 61 24 2 Door shelf 3 pieces 200 71 72 02 2 Baffle 200 74 19 15 9 Jet No 39 293 27 81 01 2 Electrode 293 06 97 07 9 Burner 293 20 52 01 8 Thermocouple 293 ...

Page 15: ...t hand side of the wire shelf and let the left hand side slide out of the holes in the wall Slide the plastic plugs into the holes of the wall Snap the shelf locks onto the wire shelf Slide the shelf into the holes on the right hand side Insert the ends of the wire shelf on the left hand side at the desired position Removing and replacing of shelves General The number of shelves and position may v...

Page 16: ...16 RM2354 MO FO 0438 ...