background image

12

MAINTENANCE & SERVICE

The user should be aware of service that must be
done on a regular schedule to keep the refrigerator
operating properly. The service should only be per-
formed by a qualified technician who is familiar with
LP gas systems and refrigerators.

1. HEATER

The heat necessary for the operation of an absorption
cooling unit is supplied by an electric heater mounted in
a pocket of the boiler system.
This model is equipped with two electric heaters, one for
120 volt AC and one for 12 volt DC.

To replace the heater proceed as follows:

1. Unplug the refrigerator power cord from the 120-

volt AC outlet.

2. Disconnect or shut off the 12 volt DC power to the

refrigerator.

3. Remove the power module cover see FIG. 1.

4. Disconnect the 120 V AC heater leads from the

power module or the 12 V DC lead from the relay.

5. With a pair of pliers unfold the lug holding the lid

of the boiler casing and open the lid.

6. Remove some insulation wool so that the heater

is accessible.

7. Turn and lift the heater out of its pocket.

8. Fit the new heater into the pocket.

9. Connect the heater leads and put on the power

module cover.

10. Reset the insulation and close the lid of the boiler.

2. REFRIGERATOR REMOVAL

Before working on the refrigerator, make sure the AC
voltage and DC voltage leads are disconnected. Shut off
the gas supply at the LP tank. Disconnect the gas sup-
ply line at the rear of the refrigerator, see FIG. 1.
Always use a back up wrench when loosening and tight-
ening connections.

Cap the gas supply line, loosen the screws anchoring
the refrigerator to the enclosure and slide the refrigera-
tor out of the compartment.
When replacing the refrigerator make sure that the seal-
ing strips are properly positioned.
Replacement is the reverse of removal. Check all con-
nections for gas leaks.
Refer to section INSTALLATION, page 4 to 8.

3. PERIODIC MAINTENANCE

To keep your Dometic refrigerator operating efficiently
and safely, periodic inspection and cleaning of several
components once or twice a year is recommended.

A. It is important to keep the area at the back of the

refrigerator clean. Check the lower vent, upper vent
and area between these openings for any obstruc-
tions such as bird/insect nests, spider webs, etc.
Clean the coils on the back of the refrigerator. Use a
soft bristled brush to dust off the coils.

It is important to keep the refrigerator area free from
combustible material, gasoline and other flammable
vapors or liquids.

NOTE: The following maintenance is required once or
twice a year, but should only be done by a qualified ser-
viceman who is familiar with LP gas systems and refrig-
erators.

B. Check all connections in the LP gas system (at the

back of the refrigerator) for gas leaks. The LP gas
supply must be turned on. Apply a non-corrosive
bubble solution to all LP gas connections.

The appearance of bubbles indicates a leak and
should be repaired immediately by a QUALIFIED
SERVICEMAN WHO IS FAMILIAR WITH GAS SYS-
TEM AND REFRIGERATORS.

! WARNING

DO NOT use a flame to check for gas leaks.

GAS EQUIPMENT ASSEMBLY

FIG. 9

INLET FITTING

NUT

MANUAL SHUTOFF VALVE .
Shown in open position

PRESSURE TEST PORT .

BURNER JET .

 BURNER MOUNTING SCREW

 BURNER TUBE

 SPARK ELECTRODE

THERMOCOUPLE

SOLENOID VALVE .

Summary of Contents for RM2354

Page 1: ...ppliance WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or additional information consult a qualified installer service agency or the gas supplier Pour votre sécurité Si vous sentez une odeur de gaz 1 Ouvrez les fenêtres 2 Ne touchez à aucun interrupteur 3 Éteignez toute flamme nue 4 Avertissez immé...

Page 2: ......

Page 3: ...tor control panel FIG 2 ON OFF AC DC GAS AUTO CHECK COLD 1 2 3 4 5 COLDEST Travel latch 1 2 3 4 F C B A C E LEGEND 3 WAY AMES Model 1 Main Power Button ON OFF 2 DC Mode Selector Button 3 AUTO GAS Mode Selector Button 4 Temperature Selector Button A DC Mode Indicator Lamp B AC Mode Indicator Lamp C GAS Mode Indicator Lamp D AUTO Mode Indicator Lamp E CHECK Indicator Lamp Gas Operation Only F Temper...

Page 4: ... the mobile home or recreational vehicle Openings for air supply or for venting of combustion products shall have a minimum dimension of not less than 1 4 inch Proper installation requires one lower fresh air intake and one upper exhaust vent The ventilation kits shown in this instruction manual have been certified for use with the refrigerator models listed in the Table For Certified Vent System ...

Page 5: ... the bottom of the lower side vent to the roof material For ventilation height see table VENTILATION HEIGHTS See Figures 3a 3b and 4 This method of installation and these clearances will give you adequate space for service and proper installation Refrigerator Minimum ventilation heights in inches and mm model installation with Installation with roof RM2354 upper and lower vent and lower side side ...

Page 6: ...ront frame the refrigerator is to be se cured in the enclosure with five screws not included The screws have to be installed in the following order STEP 1 Four screws installed through the front frame See fig 7 STEP 2 One screw installed in rear base See fig 7 In the parts bag there are plugs to be snapped in the front frame to cover the four screw heads Drain water hose A hole must be drilled thr...

Page 7: ...ong from this plug The free length of the cord is 2 feet and therefore recommended that the receptacle be located to the left side of the refrigerator viewed from the rear and approximately 4 6 inches from the floor see FIG 8 This allows easy accessibility through the vent door The cord should be routed to avoid contacting the burner cover flue cover or any other components that could damage the c...

Page 8: ... see FIG 1 This refrigerator is equipped with a semi Automatic Energy Selector AMES control system which can be set to automatically select either 120 volt AC or LP gas operation AUTO mode or if desired LP gas only GAS mode On 3 way model the control system can manu ally be set to DC operation DC mode The refrigerator controls will work down to 9 6 volt DC PANEL DIMENSIONS MAX THICKNESS 5 32 4 mm ...

Page 9: ...0 volts AC is not available the GAS mode indicator lamp C will illuminate and the control system will automatically switch to GAS operation 3 If the CHECK indicator lamp E illuminates and the GAS mode indicator lamp C is off the controls have failed to ignite the burner in the GAS mode GAS operation may be reset by pressing the main power ON OFF button 1 to the OFF then ON posi tion See step 2 und...

Page 10: ...ator lamp will not go off until the main power ON OFF button is pressed to the OFF then ON position DC MODE When operating in the DC mode the DC mode indicator lamp A will be illuminated All other mode lamps will be off The DC mode overrides all other operating modes If one of the other operating modes is desired the DC selector button 2 must be pressed to turn OFF the DC lamp A IMPORTANT To preve...

Page 11: ...e lower compartment may be frozen if the set ting is left on COLDEST position Total Refrigerated Volume 3 cu ft DEFROSTING Shut off the refrigerator by pressing the main power ON OFF button to the UP OFF position Empty the refrig erator leaving the drip tray under the finned evaporator and the cabinet and freezer doors open Defrosting time can be reduced by filling the ice trays with hot water and...

Page 12: ... line loosen the screws anchoring the refrigerator to the enclosure and slide the refrigera tor out of the compartment When replacing the refrigerator make sure that the seal ing strips are properly positioned Replacement is the reverse of removal Check all con nections for gas leaks Refer to section INSTALLATION page 4 to 8 3 PERIODIC MAINTENANCE To keep your Dometic refrigerator operating effici...

Page 13: ...DO NOT use a wire or pin when cleaning the burner jet as damage can occur to the precision opening This can cause damage to the refrigerator or create a fire hazard FIG 11 Electrode Burner tube 1 8 to 3 16 3 5 mm Clear blue color of flame FIG 10 WARNING 10 Reinstall burner being careful that the end of the burner fits into the slot on the burner bracket Check to make sure slots are centered under ...

Page 14: ...e dept for assistance SPARE PARTS The following list is a list of commonly used parts which should be available if required from your Dometic Ser vice Center Part No Description 17 37 35 06 9 Heater 150W 12V 17 37 71 02 3 Heater 175W 120V 200 22 61 24 2 Door shelf 3 pieces 200 71 72 02 2 Baffle 200 74 19 15 9 Jet No 39 293 27 81 01 2 Electrode 293 06 97 07 9 Burner 293 20 52 01 8 Thermocouple 293 ...

Page 15: ...t hand side of the wire shelf and let the left hand side slide out of the holes in the wall Slide the plastic plugs into the holes of the wall Snap the shelf locks onto the wire shelf Slide the shelf into the holes on the right hand side Insert the ends of the wire shelf on the left hand side at the desired position Removing and replacing of shelves General The number of shelves and position may v...

Page 16: ...16 RM2354 MO FO 0438 ...