CLEARANCES
Minimum clearances in inches to combustible materials are
G. Top 0
K. Side 0
L: Bottom 0
M: Rear 1
N: See example below
Clearance M between the rearmost part of the refrigerator and
the wall behind the refrigerator
Clearance N on top of the condenser is related to the minimum
ventilation height
See Fig 11 and examples below
Fig.1 1
Refrigerator Overall product Installation product Recess
Distance between
model dimensions dimensions dimensions top of condenser
and top of
Height Width Depth Height
Width Depth Height Width Depth refrigerator
A B
C h
W
d H
W D e
inch
30 3/8 21 11/16 22 1/16
20 1/4 20 3/8 29 3/4 20 1/2 21 3/8 1 1/4
RM2400 inch
32 15/16 23 24 11/16 32 1/8 21 9/16 22 15/16 32 5/16 21 13/16 23 15/16 1 1/4
RM2500 inch
40 13/16 23 24 11/16 40 21 9/16 22 15/16 40 3/16 21 13/16 23 15/16 1 1/4
RM2600 inch
52 23 24 11/16 51 3/16 21 9/16 22 15/16 51 3/8 21 13/16 23 15/16 1 1/8
RM2800 inch
57 15/16 24 15/16 24 11/16 57 1/8 23 7/16 22 15/16 57 1/2 23 13/16 23 15/16 1 1/8
This method of installation and these clearences will give you adequate space for servicing and proper installation.
d
e
h
EXAMPLES
The clearance N for the RM 2300 model is derived at in the
following way.
Installation with upper and lower side vents
N= Minimum ventilation height 37 minus installation height
29 9/16 plus distance between condenser top and refringera-
tor top 1 114
in: N=37-29 9/16+1 1/4=8 11/16 inches
mm: N=940-751+32=221 mm
Installation with roof vent and lower side vent
N=Minimum ventilation height 31 minus installation height
29 9116 plus distance between condenser top and refrigera-
tor top 1 114 plus distance between roof surface and roof vent
cap 5 114
in: N=31 -29 9/16+1 1/4+5 1/4=7 15/16 inches
mm: N=787-751+32+134=202 mm
Fig.1 2
View from above
Summary of Contents for RM2300