background image

REFRIGERATORS WITH

 IGNITER

RM 2300/2400

-36

E DCB A

39

Fig.1

Item Description

No.

1 Retainer

2

 

Thermo electric safety valve

3 Thermo couple element
4 Coupling
7 Thermostat
9 Cut-off valve

10 Nipple
11 Nut
14 Switch

23 Lighter
26 Burner
27 Electrode
29 Terminal
30 Sealing ring
31 Snap catch
33 Burner housing

35 Burner retainer
36 Terminal 12/120V
38 Burner jet
42 Plug
43 Cover
46 Cover

47 Flue baffle
50 Heater
52 Bushing
53 Retaining ring

30

Summary of Contents for RM2300

Page 1: ...all your gas supplier FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vi cinity of this or any other appliance Page Installation 5 8 Instructions for use 9 10 Gas equipment 10 Electric equipment 10 11 Maintenance 11 Fault tracing 11 Door panel 12 mD emetic 1 I quality leisure line products SERVICE OFFICE DOMETIC SALES CORP 509 South Poplar LaGrange IN 4676...

Page 2: ...valve 3 Thermo couple element 4 Coupling 7 Thermostat 9 Cut off valve 10 Nipple 11 Nut 14 Switch 23 Lighter 26 Burner 27 Electrode 29 Terminal 30 Sealing ring 31 Snap catch 33 Burner housing 35 Burner retainer 36 Terminal 12 120V 38 Burner jet 42 Plug 43 Cover 46 Cover 47 Flue baffle 50 Heater 52 Bushing 53 Retaining ring 30 ...

Page 3: ...urner jet Thermo couple element 43 Cover Coupling 46 Cover Thermostat 47 Flue baffle Cut off valve 50 Heater Nipple 51 Bushing Nut 52 Switch Clamping plate 53 Flue top Reigniter 55 Label for 12V Burner 57 Burner retainer Electrode 59 Push rod Terminal block 60 Shaft thermostat Sealing ring 61 Shaft switch Snap catch 62 Lead for 12 120V Burner housing 64 Flexible cord 3 ...

Page 4: ...ple element Coupling Thermostat Cut off valve Nipple Nut Switch Reigniter 24 Gas tube 29 Terminal block 31 Snap catch 32 Burner 33 Electrode 36 Terminal block 36 Burner jet 43 Cover 46 Nipple 47 Flue baffle 50 Heater 51 Nipple 54 Flue cap 55 Protection plate 59 Push rod 60 Shaft thermostat 61 Shaft switch 64 Flexible cord 67 Burner housing ...

Page 5: ...with a 3 8 SAE UNF 5 8 18 male flare connection All completed connections should be checked for leaks with soapy water The gas supply system must incorporate a pressure regulator to maintain a supply pressure of not more than 11 inches water column When testing the gas supply system at test pressures in excess of 1 2 psig the refrigerator and its individual shutoff valve must be disconnected from ...

Page 6: ...t Loosen the screws fixing the refrigerator to the enclosure and remove the refrigerator When replacing the refrigerator make sure that the sealing strips are properly positioned After reassembly the gas connection should be checked for leaks TEST OF THE GAS SAFETY SHUTOFF The gas safety shutoff device must be tested after the refrigera tor is placed in operation Refrigerator wlth piezo ignitor Fi...

Page 7: ... METHODS OF INSTALLATION The methods of installation are shown in figures 10 a and 10 b It is essential that all maxlmum or minimum dimensions are strictly maintained as the performance of the refrigerator is dependent on an adequate flow of air over the rear of the refrigerator VENTILATION HEIGHTS Minimum ventilation heights in inches and mm RM2300 in 37 31 RM2400 in 3 4 RM2500 in 42 RM2600 in 5 ...

Page 8: ... 40 3 16 21 13 16 23 15 16 1 1 4 RM2600 0 inch 52 23 24 11 16 51 3 16 21 9 16 22 15 16 51 3 8 21 13 16 23 15 16 1 1 8 RM2800 0 inch 57 15 16 24 15 16 24 11 16 57 1 8 23 7 16 22 15 16 57 1 2 23 13 166 23 15 16 1 1 8 This method of installation and these clearences will give you adequate space for servicing and proper installation d e T h EXAMPLES The clearance N for the RM 2300 model is derived at ...

Page 9: ...essed When lamp E goes out wait 15 sec and release button C If the lamp comes on again repeat the procedure If flame blows out reignition will take place automatically To shut off the refrigerator turn the knob A to off position Electric Operation Fig 1 2 3 1 Check that the 120 Volt plug is correctly connected to the main supply When the refrigerator is equip ped for 12 Volt D C operation the low ...

Page 10: ...le The flue baffle is suspended from the top and must be in position 2 Disconnect the heater leads in the central tube of the cooling unit 3 Pull off the metal hose The Flame Failure Safety Device The tip of the thermo couple must reach in over two slots of the burner To replace the thermocouple pro ceed as follows 1 2 3 4 5 6 7 Remove the cover Unscrew plug and pull thermocouple straight out Remo...

Page 11: ......

Page 12: ...or frame 3 Rend the panel gently so that the free side of the panel can be slipped into the corresponding groove of the door frame 4 Push the panel downwards so that the lower horizontal edge of the panel is fitted into the bottom groove 5 Between the upper edge of the panel and the door frame there is now a gap which should be covered by the decora tion strip Put the strip across the door so that...

Reviews: