Inflamable material should not be in immediate proximity to the burner.
The gas connection to the appliance is effected by means of a suitable
coupling tube fitting L8, DIN 2353-ST, complying with EN 1949 (e. g. Ermeto).
The gas connection may only be carried out by a qualified
personnel.
24
Following proper installation, a testing for leakage and a flame test must be car-
ried out by *qualified personnel in compliance with EN 1949 .
A certificate of testing must be issued.
* qualified personnel
Qualified personnel are accredited experts who are able, by virtue of their training and knowledge,
to vouch for the correct implementation of the leakage test.
The refrigerator must be equipped with a gas cock
(C) in the supply line to allow the supply to be disconnected.
Such a cut-out device must be readily accessible to the user.
C
SW 14
SW 17
A
AT
TT
TE
EN
NT
TIIO
ON
N
20 Nm
max
15 Nm
max
Gas pressure
Category I
3P(30)
I
3P(37)
I
3P(50)
I
3+
I
3B/P(50)
I
3B/P(30)
mbar 30
37
50
28-37
30-37
50
30
BE
•
DK
•
DE
•
•
FI
•
FR
•
GR
•
•
IE
•
•
IS
•
IT
•
LU
•
•
NL
•
•
NO
•
AT
•
•
PT
•
•
SE
•
CH
•
•
ES
•
UK
•
•
•