18
INSTALLATION GUIDE
On installation of the appliance, the technical and administrative regulations of the
country in which the vehicle will first be used must be adhered to. Otherwise the
refrigerator must be installed as described in these instructions. In some OEM appli-
cations it may not be possible for these instructions to be followed exactly. In this case
an authorised Dometic representative may issue supplementary instruction
In Europe, for example, gas appliances, cable laying, installation of gas
cylinders, as well as approval and checking for leaks must comply with
EN 1949 for liquid gas units in vehicles.
Installation
The appliance and its fume extraction shall be installed in such a way as to be acces-
sible for servicing at all times and must be capable of easy removal and installation.
The appliance may only be installed by authorised personnel.
Installation and connection of the appliance must comply with the latest
technical regulations, as follows:
The electrical installation must comply with national regulations.
Technical regulations EN 60335-1, EN 60335-2-24, EN 1648-1 , EN 1648-2
The gas installation must comply with national regulations.
Technical regulations EN 1949
Technical regulations EN 732
Local and building control department requirements
The appliance shall be installed in such a way that it is shielded from
excessive heat radiation.
Excessive heat impairs performance and raises the energy consumption of the
refrigerator.
Side installation
If the appliance is installed on the same side of the vehicle as the entrance
door, it is desirable that the door does not cover the refrigerator’s vents. If this cannot
be avoided there must be a gap of at least 25mm between the door and the vents.
Rear installation
If the refrigerator is mounted at the rear of the vehicle you must ensure the lower grille
is not covered by the bumper or rear lights. This would be prevent the air from circula-
ting properly and cause problems in warm weather.
6
6..0
0
6.1
6.1.1
Any installation that is not carried out by qualified persons will jeo-
pardize the manufacturer's guarantee.
Air vent grille not
blocked: OK!
6.1.2
An installation that is not carried out by qualified persons causes a
reduction in the cooling capacity and will jeopardize the manufactur-
er's guarantee.