14
Fig. 20
Fig. 24
Seal the mounting frame
making it waterproof
(
does not apply for
mounting frames with
integral seal).
1
Fig. 21
Insert frame and screw
into position
2
To install the ventilation grilles, cut two rectan-
gles (
451 mm x 156 mm
) in the outer wall of
the vehicle (
for position of the cuts, see point
4.2).
Fig. 22
Insert and lock ventilati-
on grille.
3
Fig. 23
Clip the insert for flue
gas duct in position (
only
for L100 upper ventilati-
on system kit).
4
Insert winter cover.
5
The exhaust gas duct system must be made in
such a manner as to achieve a complete
extraction of combustion products to the out-
side of living space. The duct system must
slope in an upward direction in order to avoid
a build-up of condensate. The type of exhaust
gas duct shown in Fig. 25 allows the installati-
on of the winter cover next to
A
(Fig. 25).
4.4
Exhaust gas duct and instal-
ling the fume flue
An installation other than described will
reduce the cooling capacity and jeopardi-
se the manufacturer's warranty/product
liability.
CAUTION!
Installing the standard fume flue (Fig. 25)
1.
Connect T-piece (E) to adaptor (F) or flue pipe
(K) as required and affix with screw (G).
Ensure that heat baffle (H) is lodged in the cor-
rect position.
2.
Insert flue pipe with cover plate (C) through
the appropriate aperture in the upper frame (I)
and connect to T-piece (E). If necessary, shor-
ten flue pipe (C) to the required length.
3
.
Insert
LS 100
ventilation grille (D) into moun-
ting frame (I) and fasten, using the locking
handle on the left of the grille.
4
.
Put cap (B) on flue pipe (C).
5
.
Insert extractor insert (A) into ventilation grille
(D).
Installation